TROUBLESHOOTINGCondition Possible faults Possible procedureThe battery warning LED flashes. Temperature deviation, the battery istoo cold or too hot to use.Let the battery cool down or move it indoors to warm it up. When thebattery has the correct temperature, it can be used again. The batterywill not charge if the battery temperature is more than 50 °C (122 °F).Use the battery in ambient temperatures between -10 °C (14 °F) and 40°C (104 °F).Use the battery charger in ambient temperatures between 5 °C (41 °F)and 40 °C (104 °F).The battery is empty. Charge the battery.The battery warning LED comes on. Permanent battery error. Speak to your dealer.TRANSPORTATION AND STORAGE• The supplied Li-ion batteries obey the Dangerous Goods Legislationrequirements.• Obey the special requirement on package and labels for commercialtransportations, also those from third parties and forwarding agents.• Speak to a person with special training in dangerous material beforeyou send the product. Obey all applicable national regulations.• Use tape on the contacts when you put the battery in a package. Putthe battery in the package tightly to prevent damage and accidents.• Do not keep the battery in an area where static electricity can occur. Donot keep the battery in a metal box.• Put the battery in a dry, frost free and clean space with correcttemperature.• Put the battery in storage where the temperature is between 5 °C (41°F) and 25 °C (77 °F). Keep the battery away from sunlight.• Charge the battery 30% to 50% before you put it in storage for longperiods.• Clean the battery before you put it in storage.DISPOSALHusqvarna products are not domestic waste and must only be discarded asgiven in this manual.6 1648 - 003 - 07.11.2022