TroubleshootingKeypadLED screen Possible faults Possible solutionsThe error LED flashes. Overload The cutting attachment cannot movefreely. Release the cutting attach-ment.The product does not start. There is dirt in the battery connec-tors.Clean the battery connectors withcompressed air or a soft brush.The error LED comes on with redlight.It is necessary to do servicing on theproductSpeak to your service dealer.BatteryLED display Possible faults Possible actionThe green LED flashes. Low battery voltage. Charge the battery.The error LED flashes. Temperature deviation. Use the battery in temperatures between-10°C (14°F) and 40°C (104°F).Too much voltage. Make sure that the mains voltage aligns withthe voltage stated on the rating plate of theproduct.Remove the battery from the battery charger.The error LED is on. Cell difference is too much (1V). Speak to your servicing dealer.Battery chargerProblem Possible faults Possible solutionRed error LED flashes. Temperature deviation. Use the battery charger in tempera-tures between 5 °C (41 °F) and 40 °C(104 °F).Red error LED comes on. Too much cell difference (1V). Speak to your servicing dealer.Transportation, storage and disposalTransportation and storage• The supplied Li-ion batteries obey the DangerousGoods Legislation requirements.• Obey the special requirement on package and labelsfor commercial transportation, including by thirdparties and forwarding agents.• Speak to a person with special training in dangerousmaterial before you send the product. Obey allapplicable national regulations.• Use tape on open contacts when you put the batteryin a package. Put the battery in the package tightlyto prevent movement.• Remove the battery for storage or transportation.1637 - 003 - 06.04.2021 15