Honeywell TC844A1015 Installation Instructions Manual
FCC StatementThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) thisdevice must accept any interference received, including interference that may cause undesired operation.NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed toprovide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if notinstalled and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will notoccur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off andon, the user is encouraged to try to correct the interference by one or more of the following measures:– Reorient or relocate the receiving antenna.– Increase the separation between the equipment and receiver.– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.– Consult the dealer or an experienced radio/TV technician for help.H500-32-00 4 I56-1982-004R© 2006 Honeywell1. Grasp the Filtrex housing with one hand and the cover with the other. Turn the cover counterclockwise fully (approx. 30 degrees)and remove cover by pulling it away from detector unit (see Figure 4).2. Replace with new filter and cover assembly. The cover is keyed so it fits in place only one way. Turn the cover clockwise until it stops.NOTE: The base is equipped with an optional tamperproof feature which can be used to prevent unintentional removal of Filtrex whilereplacing the filter.If a clogged filter was the cause of the trouble condition, normal detector operation should resume automatically within five minutes. Ifthe trouble condition persists, the detector must be returned for repair or replacement.Installing Filtrex into Base1. Align the detector at a right angle to the base, with the five wires and connector adjacent to the connector receptacle as shown inFigure 5.2. Plug the wired connector into the receptacle.3. Rotate the detector into the base, making sure detector and base keyed fit is lined up. Turn the detector clockwise until it snapsinto place.IMPORTANT: Filtrex will only operate with 14507371-008/B524FTXE Mounting Base.SPECIAl NOTE REgARdINg SMOkE dETECTOR guARdSSmoke detectors are not to be used with detector guards unless the combination has been evaluated and found suitable for that purpose.Figure 5: Installing Filtrex detector into base:Before installing sensors, please thoroughly read the Guide for Proper Useof System Smoke Detectors, which provides detailed information on sensorspacing, placement, zoning, and special applications. Copies of this guideare available from Honeywell.NOTICE: This manual should be left with the owner/user of this equipment.IMPORTANT: This sensor must be tested and maintained regularly followingNFPA 72 requirements. It should be cleaned at least once a year.gENERAl dESCRIPTIONFiltrex® uses a small air intake fan and a high density replaceable filter. Airand smoke are drawn into a photoelectric sensing chamber while airborneparticulate and water mist are removed. The addressable-analog detectortransmits an analog representation of smoke density over a communicationline to a control panel. FlashScan Technology is a new communication proto-col that greatly enhances the speed of communication between analog intel-ligent devices. Rotary-decade switches are provided for setting the sensor’saddress. Two LEDs on the sensor are controlled by the panel to indicatesensor status.The Filtrex smoke detector is intended for use in normal environmental conditions, where dust and other airborne particulate are pres-ent at elevated levels. These elevated levels tend to cause false alarms and high maintenance in standard detectors. Filtrex providesa protective enclosure for a photoelectric smoke detector chamber and allows smoke detection in areas where heat detection was theonly practical alternative for fire sensing.Filtrex requires compatible addressable communications to function properly. Connect this detector to listed-compatible control panels only.SPECIFICATIONSOperating Voltage Range: 15 to 32 VDCDetector Current: 230 μA @ 24 VDC (without communication)285 μA @ 24 VDC (one communication every 5 sec. with LED enabled)Auxiliary Power Supply Voltage: 15 to 30 VDC filtered; Ripple voltage may not drop below 15 volts.Auxiliary Power Supply CurrentPeak: 123 mA max.Average: 27 mA max.Operating Humidity Range: 10% to 93% Relative Humidity, non-condensingOperating Temperature Range: 0° to 50°C (32° to 122°F)Height: 2.8 inches (43 mm)Diameter: 6.1 inches (155 mm) installed in 14507371-0084.0 inches (102 mm) installed in B524FTXEWeight: 7.3 oz. (207 g)Mounting Base: Requires 14507371-008 (U.S.), B524FTXE (Europe)WARNINgFiltrex is not designed to operate in explosive environments.H500-32-00 1 I56-1982-004RHoneywell, 1985 Douglas Drive North, Golden Valley, MN 55422Model TC844A1015 Filtrex Intelligent Photoelectronic Sensorwith FlashScan TechnologyC0193-00I56-1982-004R0845-CPD.232.1427SYSTEM SENSOR3825 OHIO AVENUE, ST. CHARLESIL, 60174 8021 U.S.A.EN54-7Model TC844A1015Filtrex Point Optical Smoke Sensor for Harsh AreasInstallation InstructionsPlease refer to insert for the Limitations of Fire Alarm Systems |
Related manuals for Honeywell TC844A1015
Honeywell Gent Vigilon Installation Instructions Manual
Honeywell ESSER 761694 Installation Instructions Manual
Honeywell XLS140 Installation Manual
Honeywell SMX-AUS Installation Manual
Honeywell 6808 Installation And Operation Manual
Honeywell NOTIFIER NFX-SMT3 Installation And Maintenance Instructions Manual
Honeywell ESSER IQ8MCP Installation Instruction
Honeywell NOTIFIER AM-8000 Installation Manual
Honeywell ESSER 804902 Installation Instruction
Honeywell ESSER 804950 Installation Instruction
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved