71Verifying the installationLog in to HDM to verify that the mLOM Ethernet adapter is operating correctly. For more information,see HDM online help.Installing a PCIe Ethernet adapterProcedure1. Power off the server. For more information, see "Powering off the server."2. Remove the server from the rack. For more information, see "Removing the server from a rack."3. Remove the access panel. For more information, see "Removing the access panel."4. Install the PCIe Ethernet adapter. For more information, see "Installing riser cards and PCIemodules."5. To use a port on the Ethernet adapter as the HDM shared network port, connect the NCSItransit cable to the PCIe Ethernet adapter. For more information, see "Connecting the NCSItransit cable for a PCIe Ethernet adapter."6. Connect network cables to the PCIe Ethernet adapter.7. Install the access panel. For more information, see "Installing the access panel."8. Rack-mount the server. For more information, see "Rack-mounting the server."9. Connect the power cord. For more information, see "Connecting the power cord."10. Power on the server. For more information, see "Powering on the server."Verifying the installationLog in to HDM to verify that the PCIe Ethernet adapter is operating correctly. For more information,see HDM online help.Installing SATA M.2 SSDsGuidelinesThe SATA M.2 SSDs can only be installed in drive cage bay 1 on a UIS-Cell 3010 G3 server. Formore information about the location of drive cage bay 1, see "Front panel view."SATA M.2 SSDs and the SATA optical drive have the same installation location. You can install onlyone of them.If you are installing two SATA M.2 SSDs, you must install a standard storage controller. In thiscondition, connect the data cable of the front drive backplane to the standard storage controller.You can install a maximum of two SATA M.2 SSDs on an M.2 SSD expender module. The installationprocedure for the two SSDs is the same. In this example, only one SATA M.2 SSD is installed.Procedure1. Power off the server. For more information, see "Powering off the server."2. Remove the server from the rack. For more information, see "Removing the server from a rack."3. Remove the access panel. For more information, see "Removing the access panel."4. Remove the chassis air baffle. For more information, see "Removing air baffles."5. Remove the fan cage. For more information, see "Replacing the fan cage."6. Remove the security bezel, if any. For more information, see "Replacing the security bezel."7. Remove the blank from drive cage bay 1, as shown in Figure 102.8. Remove the expander module blank, as shown in Figure 103.9. Install the M.2 transfer module to drive cage bay 1, as shown in Figure 104.