SPECIFICATIONSInput Voltage: 120 VAC, 208/240 VAC, or 277 VAC in all units basedupon dipswitch configuration.Switch Rating: DPDT ModelsNormally Open Contacts40A Resistive, 120-277Vac.30A General Purpose, 120-277Vac.20A Resistive, 30Vdc1 HP, 120Vac ; 2HP, 240Vac ;20A Ballast, 120-277Vac.15A Tungsten, 120Vac5.4A Tungsten, 208-277Vac.800VA, Pilot Duty, 120Vac.720VA, Pilot Duty, 240-277Vac.TV-5, 120VacNormally Closed Contacts30A Resistive, 120-277Vac15A General Purpose, 120-277Vac15A Resistive, 30Vdc20A Ballast, 120-277Vac1/4HP, 120Vac; 1/2HP, 208-240Vac.290VA, Pilot, 120Vac.360VA, Pilot, 208-240Vac.NOTE: If loads are connected to both NC and NO contacts, both contacts arederated to 67% of the above values.ENVIRONMENTAL RATINGSAmbient Temperature: –40F to 130FHumidity: 0-95% RH, Non-condensingWIRING CONNECTIONSScrew clamp terminals for up to 2, 8 AWG wires per position. For supplyconnections, use 8AWG or larger wires suitable for at least 105° C. Use copperconductors only.LightsPower LED (Orange) – Light illuminates when power is applied tothe timerStatus LED (Green) – Light illuminates when power is applied to load.INSTALLATIONCAUTION: Before wiring or service, power to this time switch and theequipment it controls must be turned off. Turning off the timer switchonly will not prevent a shock hazard. Replace cover plate within housingbefore supplying power to time switch. Installation should be performedby a licensed electrician only. Before installing this product, read allinstructions carefully. Remove protective cover panel within time-switchhousing by removing screws located below timer face.Dipswitch ConfigurationWARNING: Failure to properly configure the dipswitch will result indamage to the unit and void the warranty! Before installing and wiring the GETime Switch, proper configuration must be selected. This is accomplished asfollows:120VAC 277VAC (Default)208~240VACON OFF ON OFFON OFFALL ON ALL OFF1 & 4 OFF2 & 3 ONDigital Time SwitchNOTE: For outdoor locations, rain-tight or wet-location conduit hubs thatcomply with requirements of UL 514B (standard for fittings for conduit andoutlet boxes) must be used.1. To mount the box, remove the timer mechanism. Push the latch at thetop of the timer mechanism. The mechanism will release and pull out ofbox.2. Select knockouts to be used. Remove the inner 1/2” knockout byinserting a screwdriver in the slot and carefully punch knockout loose.Remove slug. If the 3/4” knockout is required, remove the outer ringwith pliers after removing the 1/2” knockout. Smooth edges with file ifnecessary.3. Place enclosure in desired mounting location and mark the threemounting holes.4. Drill holes for #8 screws using 1/8” drill bit, start screws in holes.5. Place enclosure over screws and tighten screws.6. Connect conduit hubs to conduit before connecting the hubs to theenclosure. After inserting hubs into enclosure, carefully tighten hub locknut. Do not over-tighten.7. Install in accordance with all applicable national and local coderequirements. See Figure 1 and wiring diagrams.8. To place the timer mechanism back in the metal box timer first hold topof the timer mechanism. Slide the plastic case into the metal box latchesin the center of the metal box. Push the top of the timer mechanism untilthe metal latch snaps into place.GROUNDING: This enclosure has a grounding block on the bottom/inside of the timer box. Screw in all ground wires to the ground block.A pool application does not require bonding.This enclosure does not provide grounding between conduits. When usingnon-metallic conduit or cable, connect the ground wires of all cables togetherwith a wire nut. When metallic conduit is used, use grounding-type bushingsand a jumper wire between each conduit.15136 |
Related manuals for GE 15136
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved