The following steps describe provisioning for one NE in detail. Remember this provisioning is required for eachNE involved in the network of OSC-linked NEs connecting the current NE (being turned up) with the DCN.Step 1Change to CLI configuration mode.Command:> configureConfigure NEM InterfaceStep 2Create the NEM interface and set its IP address.Command:% set interfaces interface ip-1/0/0/NEM type ip ipv4 forwarding true address prefix-length preferred trueParameter Value Descriptionip_address <1xx.xxx.xxx.xxx> IP address of the NEM interfaceprefix-length <0…32> Length of the subnet prefixCommand Example:% set interfaces interface ip-1/0/0/NEM type ip ipv4 forwarding true address2.2.2.2 prefix-length 32 preferred trueConfigure IP Interfaces for OSC LinksPrerequisite:■ All provisioning for each OSC link is complete, including provisioning of the ETH interface on the E-SC-E1 port.Step 3Create an IP interface on the E-SC-E1 port that supports the OSC link. Configure this IP interface to share theNEM IP address.Command:% set interfaces interface type ip ipv4 enabled forwarding trueaddress-src ip-1/0/0/NEM mtu Parameter Value Descriptioninterface /0/0/E-SC-E1> IP interface on the E-SC-E1 port that supports the OSC linkInitial System Turn UpConfigure IP Connection to DCN180Release 19.1.1 · Issue 1.1, May 2021 Fujitsu and Fujitsu Customer Use Only PreviousNext |