32 Installation manual4 Test runTest run the system when the installation completed.Select a wash program, start the washer extractor and observe a test load to ensure that all products dispense onlywhen they are supposed to dispense.5 Technical specification• Number of pumps which may run at one time:Non flush = AllFlush manifold = 1 at a time (pumps will queue when more than one is triggered at the same time)• Maximum pump amount = 995 ml• Maximum pump delay Time = 999 sec.• Maximum flush time = 999 sec.• Maximum pump prime time = 5 min.• Load count pump = Highest pump number in each wash program with a non-zero amount programmed• Maximum J1 cable length = 22.8 m• Maximum operating temperature = 49℃This unit complies with the following directives:• 2006/95/EC Low Voltage Directive (LVD)• 2004/108/EC Electromagnetic Compatibility (EMC)This unit has been designed and manufactured to the following specifications:EN 60370-1, EN 61000-6-2:, EN 61000-6-4:2001, EN 61000-3-2:2000, EN 61000-3-3:1995/A1:2001