PLANNINGGUIDEWeb: http://www.Dacor.comCorporate Phone: 800-793-0093Specifications are subject to change without notice.See installation instructions for additional details. 5.10Epicure™ RangesER30DElEctrical rEquirEmEntsIt is the owner’s responsibility to ensure that the electricalconnection of this appliance is performed by a qualified electrician.The electrical installation, including minimum supply wire sizeand grounding, must be in accordance with the National Electriccode ANSI/NFPA 70-1993* (or latest revision) and local codes andordinances. A copy of this standard may be obtained from:National Fire Protection Association1 Batterymarch ParkQuincy, Massachusetts 02269-9101The correct voltage, frequency, and amperage must besupplied to the appliance from a separate, grounded, circuitthat is protected by a properly sized circuit breaker or timedelay fuse. Refer to the chart below for requirements.A 4-wire connection (not provided) is required to connect therange to the junction box. The minimum wire gauge suggestedby Dacor ® is 10 AWG. Consult local building codes for thetype and minimum wire gauge to use.Suggested wiring color code: Black, white, red, and green.The wiring needs to be long enough to allow the range to be pulledout from the wall for service, while remaining connected.◊◊◊Gas supply rEquirEmEntsCheck your local building codes for the proper method ofinstallation. In the absence of local codes, this applianceshould be installed in accordance with the National Fuel GasCode ANSI Z223.1.Be certain that the appliance being installed is correct for thegas service being provided (natural gas or LP gas). Also, ifoperating the range at an altitude above 4000 ft. (1219 m)make sure it is equipped for high altitude operation. Refer tothe range data plate and the table on page 3 to determine thecorrect model.See the table below for gas supply pressure requirements.The regulator inlet accommodates a 3/4” gas line. The rangeships with a 1/2” to 3/4” adapter connected to the regulator.◊◊◊◊1/2071707GAS SUPPLY PRESSURE REQUIREMENTSGas Type Manifold Pressure Minimum GasSupply PressureNatural Gas 5” Water Column 6” Water ColumnLiquid Petroleum(LP) 10” Water Column 11” Water ColumnELECTRIC CIRCUIT REQUIREMENTSRange Model Circuit Required Total ConnectedLoadER30D 240VAC,60Hz, 30A 5.6kW (23A)GAS - ELECTRICAL ACCESS DIMENSIONS“A” “B” “C” “D” “E”4 7/8” 21 3/4” 9 1/16” 10 1/2” 7/8”BACDGas InletE Conduit ConnectionHole in BottomBack of RangeRange Electrical Access,Cover RemovedFinished SidePanel1 1/16” (27mm)26 3/8” (670mm)27 5/16” (694mm)28 13/16” (732mm)24 1/4” (616mm)3” (76mm)Backguard6” (152mm)Backguard37 1/2”(953mm)to35 3/8”(899mm)46 1/4” (1175mm)