3-33Error CodeError Code Details■ E000 to E015EcodeDetailedcodeOccuranceareaItems DescriptionE000 -0001 -05 Title Fixing belt temperature rise is insufficient at power ON.Descriptionof detectionFixing main thermistor (THM1-1) temperature doesnot reach 50 degrees Celsius within 120 seconds afterstartup of fixing belt temperature control.Measures Check if the detection temperature of the thermistor isrisen in service mode (COPIER> DISPLAY> ANALOG>FIX-xx).A. In case that either one of the thermistor detectiontemperature is risenA-1. Replace the fixing belt unitA-2. Faulty drawer connector -> Clean the drawerconnector or replace the fixing drawer cableB. In case that neither of them are not risenB-1. Check the connection of the fixing thermistor(to see if the connection of the drawer isfaulty, the connector is physically removed ordisconnected) -> replace the fixing belt unitB-2. Check the connection of the IH powerconnector (to see if the connector is physicallyremoved or disconnected, or the cable is caught)B-3. Replace the IH power unitB-4. Replace the DC controller PCBNOTE: After performing the above remedy work, gothrough the following to clear the error: COPIER>FUNCTION> CLEAR> ERREcodeDetailedcodeOccuranceareaItems DescriptionE000 -0101 -05 Title Pressure belt temperature rise is insufficient at powerON.Descriptionof detectionPressure main thermistor (THM2) temperature doesnot reach 50 degrees Celsius within 250 seconds afterstartup of pressure belt temperature control.Measures Check if the detection temperature of the thermistor isrisen in service mode (COPIER> DISPLAY> ANALOG>FIX-xx).A. In case that either one of the thermistor detectiontemperature is risenA-1. Check the pressure belt main thermistor(to see if the thermistor is disconnected, theharness of the thermistor is disconnected,foreign substance is in the thermistor, failure ofthe thermistor) -> replace the main thermistor orthe pressure stayA-2. Faulty drawer connector is a possible cause-> clean the drawer connector or replace thefixing drawer cableB. In case that neither of them are not risenB-1. Check the connection of the AC driverconnector (to see if the connector is physicallyremoved or disconnected, or the cable is caught)B-2. Replace the AC driver unitB-3. Replace the DC controller PCBB-4. Replace the pressure belt unitNOTE: After performing the above remedy work, gothrough the following to clear the error: COPIER>FUNCTION> CLEAR> ERRE001 -0001 -05 Title Abnormal temperature rise of fixing main thermistor(circuit failure)Descriptionof detectionFixing main thermistor (THM1-1) sensed an abnormalhigh temperature. (ASIC detection)Measures Check the detection temperature of the fixing mainthermistor (THM1-1) in service mode (COPIER>DISPLAY> ANALOG> FIX-UC).A. In case that the detection temperature is 250 degCA-1. The cable of the fixing main thermistor iscaught -> replace the fixing belt unitB. In case that the detection temperature is other than250 degCB-1. Replace the DC controller PCBNOTE: After performing the above remedy work, gothrough the following to clear the error: COPIER>FUNCTION> CLEAR> ERR