COPYRIGHT © 2001 CANON INC. 2000 2000 2000 2000 NM-PDL REV.0 JULY 2001CHAPTER 4 DISASSEMBLY/ASSEMBLY4-274. Connect the AC power cable to the power switch (see F04-406-05).The AC power cable consists of one blue and one brown cable.• Connect the blue cable to pin N• Connect the brown cable to pin PThe other end of the AC power cable should still be attached to the power supply.F04-406-05 Power switch pins and cables5. Connect the ground cable to pin E on the power switch (see F04-406-05).The other end of the ground cable should still be attached to the chassis ground pin. Thesecond ground cable should remain attached to the chassis ground pin and the powersupply.6. Reattach the front panel as described on page 4-7.7. Reassemble the iR-M1 and verify its functionality as described on page 4-11.Chassis ground pinAC power cable connectorAC power cable (brown) on pin PAC power cable (blue) on pin NGround cable (green) on pin EPower supplyPower switchCenter frame