Installation and connection en39Drinking water connection1. Fasten the drinking water connectionto the tap accordingto the installation instructions usingthe enclosed parts.Ensure that the drinking waterconnection is not kinked, crushedor twisted.2. When replacing the appliance,always use a new water supply hose.Water pressure:At least 0.05 MPa (0.5 bar), maximum1 MPa (10 bar). At a higher waterpressure: connect pressure-reducingvalve ahead.Inlet rate:Minimum 10 litres/minuteWater temperature:Note printing on the water inlet hose!If models are marked with 25°,the water temperature may be max.25 °C (cold water).For all other models:Cold water preferred; hot water max.temperature 60 °C.Electrical connectionConnect the appliance to analternating current only, ranging from220 V to 240 V and 50 Hz or 60 Hzvia a correctly installed socket withprotective earth conductor. Seerating plate for required fusing 92.The socket must be nearthe appliance and freely accessiblefollowing installation.If the plug is not freely accessible, anallpole disconnector with a contactopening of at least 3 mm must befitted on the installation sideto satisfy the relevant safetyinstructions.The connection may be modified bytechnicians only.A power cord extension may bepurchased from customer serviceonly.Use only a residual current operatedcircuit-breaker which featuresthe symbol ‚. Only this extensionguarantees compliance withthe currently valid regulations.The appliance features a waterdamage protection system. Pleasenote the system will not functionunless the power supplyis connected.