56/64 DecommissioningBosch Rexroth AG, Material and information flow technology: HQ 2/C-H, HQ 4, 3 842 358 792/2016-1210.4.5 Spare partsFor a list of spare parts, see MTparts, 3 842 529 770.11 DecommissioningThis product does not need to be decommissioned. Accordingly, this section hasbeen left blank.12 Disassembly and replacementWARNINGHigh electrical voltage!Risk of serious injury or death from electric shock. Disconnect the relevant system component before performing maintenance orservicing. Secure the system against unintended reactivation.High pneumatic pressure is present!Risk of serious injury or death. Switch off the compressed air supply to the relevant system component beforeundertaking any maintenance or servicing. Secure the system against unintended reactivation.Raised loads may fall!Falling objects can result in serious injury (or even death). Only use slings with a sufficiently high bearing load (see shipping documents forproduct weight). Make sure the lifting straps are correctly fastened before lifting the product. Secure the product against tipping when lifting. Make sure no one but the operator is in the danger zone when lifting and lowering.12.1 Preparing the product for storage/later use• Only set the product down on a flat surface.• Protect the product from mechanical stress.• Protect the product from environmental influences, such as dirt and moisture.• Pay attention to the ambient conditions, see page 58.• For products with ready-mounted motor: Support the product so that the motor isnot placed under mechanical load.