Error Memory | 9Bosch Motorsport Engine_Control_Unit_MS_6.x_Manual 71 / 76CW_EM_xxx Individual error related to a function0 Error will not be stored in the monitor1 Error is stored in the monitor2 Not valid3 Error is stored in the monitor and the MIL condition isswitched onThe single error bits may be collected in the error monitor.9.3 Error Memory PropertiesThe following property is available for the error memory itself.CLRERRMON Reset of the error monitorError Status /device measurement label error_state0 No error present in the memory1 At least one inactive error present in memory, no active er-rors2 At least one active error present in memoryIf displayed in a measurement sheet, this property value (0, 1 or 2) is translated into averbal description.