Note: Some cabinet finishes cannot survive thetemperatures allowed by safety standards, particularly self-cleaning ovens; the cabinets may discolor or stain. This ismost noticeable with laminate cabinets.Avoid obstructing air flowWARNINGRisk of fire - do not obstruct the vent space at therear of the range top. Do not caulk or otherwise sealthis opening.Proper vent spacing for the Dual Fuel or Gas ranges isautomatically achieved when the rear of the range isagainst the wall. If the resulting gap is obstructed, eventemporarily, the range and/or the surrounding cabinetrycould overheat, creating a fire hazard.measurements in inches (mm)* Minimum clearance of 30" required tooverhead combustible surface.if installing overhead vent or over-the-range microwave, refer to clearancesprovided with these products.Flame retardant materials bear the mark:UNDERWRITERS LABORATORIES INC. CLASSIFIEDMINERAL AND FIBER BOARDS SURFACE BURNINGCHARACTERISTICS, followed by the flame spread andsmoke ratings. These designations are shown as "FHC(Flame Spread/Smoke Developed)". Materials with "0"flame spread ratings are flame-retardant. Local codes mayallow other flame spread ratings. It is the responsibility ofthe installer to ensure installation is in accordance withthese ratings.Prepare Walls and FloorSeal any holes in the walls or floor. Remove any ob-structions (extra electrical or gas connections, etc.) so thatrange will rest against wall properly.Countertop RequirementsCountertops must be smooth and level.English 6 9001079089 Rev A