Bosch Security SystemsDivar | Installation Manual | Menu system EN | 5-14Add schedule• Select the profile name, the begin and end times, and the days onwhich you want the profile to be active.• Only five profiles changes can occur in any one day.• Select a number from 0 to 23 for the hour. Select between 0, 15, 30or 45 for the minutes.• If the begin time is later than the end time, then the profile is activefrom the end time until the begin time on the next day.>>> Exception days• Up to 32 exception days can be set that override the calendar list.• Use the up/down keys to move to an exception entry and press theselect key to start editing. Enter the start date/time, the duration andthe profile name.• Press the F2 key to empty an entry.>> PROFILE OVERRIDE• Select a different profile to manually override the active profile for atemporary period.• Set the duration for which you wish to override the active profile. Themaximum is 24 hours. If set to Always, the calendar is disabledcompletely. If set to zero, the override function is disabled.>> PROFILE MANAGER• The Profile Manager lists the scheduled and active profiles.• The Profile Override Inputs submenu sets up the inputs to switchprofiles.• The Profiles Titles submenu assigns names to the six different profiles.• The Camera Pre-position on Profile Change submenu sets fourcontrollable cameras to a specified pre-position when the active profile ischanged to a different profile.>>> Profile override inputs• Six inputs can be set up to select a profile.• The active profile defined by the calendar and exception dayschedule is overridden by the input selection as long as the input isactive.• Inputs used for other purposes cannot be used to select a profile.• An entry is set to empty by selecting it and pressing F2.>>> Profile titles• Select a profile. Enter up to 4 characters to give a meaningful nameto the profile.>>> Camera pre-position on profile change• Four controllable cameras can be set up for a profile change.• Enter the pre-position (PP00 to PP99) that each camera shouldadopt when the profile is activated. Set to None for no change.>> SYSTEM BEHAVIOR• Use the System Behavior menu to configure the event handling, therecording setup and the access restrictions for each of the six profiles.• Profile settings can be copied from one profile to another in the CopySystem Behavior submenu.>>> Event handling• Select the profile for which you wish to configure the eventhandling.• Move to the line that you wish to change. Press the camera keys toselect an input or camera. Press the select key to enable or disablethe selection. A check mark means enabled.• Enabled selections act as triggers. If alarm is checked, the selectionacts as an alarm.