Using Bosch VMS Operator ClientUse Bosch VMS Operator Client to verify the live, recording and playback functionality ofDIVAR IP.To verify live image functionality in the Operator Client1. On the Bosch VMS default screen, double-click the Operator Client icon . Theapplication starts.2. Enter the following and click OK.User name: adminPassword: no password required (if not set with the wizard)Connection: 127.0.0.13. Click the live image icon. The Logical Tree with the cameras is displayed.4. Select a camera and drag it to an image window. The image of the camera is displayed ifthe camera is assigned correctly.Note:Cameras in the image window with a red dot in the camera’s icon are viewed live.To verify recording functionality in the Operator Client4 Cameras in the Logical Tree with a red dot in the camera’s icon are recording.To verify playback functionality in the Operator Client4 The time line moves if the a camera is viewed in playback mode.To perform further functionalities refer to the Bosch VMS manual.Performance overview live4CIF2.5 Mbit 5 Mbit 10 MbitNumber of softwaremonitors20 13 9720p2.5 Mbit 5 Mbit 10 MbitNumber of softwaremonitors14 11 61080p2.5 Mbit 5 Mbit 10 MbitNumber of softwaremonitors8 6 5References to the manual are described in Additional documentation and client software, page29.4.628 en | System setup - first steps DIVAR IP 7000 1U2013.10 | V1 | DOC Quick Installation Guide Bosch Sicherheitssysteme GmbH