Access Modular Controller 2 Appendices | en 49Bosch Security Systems B.V. Руководство по установке 2022-11 | V05 |11.2.2 Firmware until 6x.45, 37.60Push Display (Example) Description0 Vaa.bb 01.05.17 aa = Reader Protocol Version37 - Wiegand, 60 - Lbus, 61 - BG900, 62 - OSDPbb = Firmware Version01.05.17 release date of the firmware (dd.mm.yy)1 S/N1: 0910024419 Serial number 18 digits - Part1 10 digits2 S/N2: 22850034 Part 2 - 8 digits3 11.18 12:24:18 S Current date and time (MM.DD hh:mm:ss)(S) = daylight saving4 Dig. IO: :::::::::::::::: Display of the digital contacts: the input signals set willbe shown with an extension above - output signals withan extension below. The first eight digits display thecontroller’s signals. The second eight digits display theextension board’s signals4a Dig. I1: ::::::::::::::::If there are I/O-Boards connected, the signals willbe shown on separate pages.4b Dig. I2: ::::::::::::::::4c Dig. I3: ::::::::::::::::5 MAC 001B860012AB Network device address (MAC)6N AMC-1234-5678Network name of the controller (max. 14 char.)SeeConfiguring Ethernet interface, page 32.7 I 192.168.10.18 IP-address of the controller8 G 192.168.10.255 IP-address of the gateway9 M 255.255.255.0 Subnetmask10 H 192.168.10.10 IP-address of the host computer11 DHCP 1 DHCP-status:1 = on0 = off12 D 192.168.10.1 IP-address of the DNS server13Host: + "C"Host activity:+ = online- = offline"C" = Counter (0 to 9) of the received data packagesfrom the host interface.RS-485 Bus connection:A = Address 1 … H = Address 814 HSC state: x Host secure status:1 = enable2 = disable