en Installation and connection12volume of refrigerant is indicatedon the rating plate. → "Appliance",Fig. 1 /6 , Page 14The weight of the appliance ex worksmay be up to 70 kg depending onthe model.The subfloor must be of sufficient sta-bility to bear the weight of the appli-ance.Permitted room temperatureThe permitted room temperature de-pends on the appliance's climateclass.The climate class can be found onthe rating plate. → "Appliance", Fig.1 /6 , Page 14Climate class Permitted room temperat-ureSN 10 °C to 32 °CN 16 °C to 32 °CST 16 °C to 38 °CT 16 °C to 43 °CThe appliance is fully functional withinthe permitted room temperature.If an appliance with climate class SNis operated at colder room temperat-ures, the appliance will not be dam-aged up to a room temperature of5 °C.Niche dimensionsObserve the niche dimensions if youinstall your appliance in the furniturerecess. If this is not the case, prob-lems may occur when installing theappliance.Niche depthInstall the appliance in the recom-mended niche depth of 560 mm.If the niche depth is smaller, the en-ergy consumption increases slightly.The niche depth must be a minimum550 mm.Niche widthAn inside niche width of at least560 mm is required for the appli-ance.Preparing the appliance forthe first time1. Remove the informative material.2. Remove the protective foil andtransit bolts, e.g. remove the ad-hesive strips and carton.3. Clean the appliance for the firsttime. → Page 19Connecting the appliance tothe electricity supply1. Insert the mains plug of the appli-ance's power cable in a socketnearby.The connection data of the appli-ance can be found on the ratingplate. → "Appliance", Fig. 1 /6 ,Page 142. Check the mains plug is insertedproperly.a The appliance is now ready foruse.