2000 Series | Program Entry Guide | 13.0 Relays EN | 56Bosch Security Systems | 7/05 | 35114FTable 18: continuedProgrammers Keypad Description2-Second Output 22 Provides a 2-second output.“And” this function to another function for a 2-second output. Refer to the Relay1 Logic 1 and Relay 2 Logic 1 prompts in Section 13.1 Relay Function Logic.For example “anding” this function to the Follow Point function results in a 2-second relay activation on a point fault.2-Second Output does not activate when alarms from A, B, C keys occur.Note:Do not “and” this function to the A,B,C Key, Momentary, A,B,C Key, Pulse, GroundStart, or Follow Alarm Output functions.Do not use this function for both Relay 1 and Relay 2.RF, Light Key 23 Pressing the [Light] key (light bulb graphic) on RF keypads toggles this relay offand on.Voice Request 24 The Voice Request Relay function is intended for use with an optional two-wayvoice verification module.The Voice Request Relay activates for 2 seconds when the acknowledgment ofan Alarm Report from an Alarm Report Delay point(Digit 2 = 2, 3, 7, or 8) is received at the control panel.Control panels with firmware revision 2.5 or earlier, Relay Function 24 does notprovide the Voice Request Relay function. For those control panels, RelayFunction 24 is RF Special Key.13.3 Relay Parameters, for KeypadProgramming OnlyThe parameter prompts shown in Table 19 are forprogramming from the keypad.If you did not program one of the Relay functions (thefirst four prompts in this group) with a Relay functionfrom 1 to 9 (refer to Table 18) or you left theRelaysGroup prompts at their defaults, leave the prompts inTable 19 at their defaults.If you selected a Relay function from 1 to 9, you needto program a parameter for that function. Read theinstructions carefully.Each relay parameter has its own group. Eachprompt in the group allows you to assign a point oruser to the Relay function. For example, if you choseAlarm for Relay 1 Function 1, use the prompts inGroup 18,Relay 1, Func 1 Parameter to tell thesystem which points you want to activate the relay.Table 19: Relay ParametersGroup Prompt Default18 Relay 1, Func 1Parameter1 Point 1 (or User 1)2 Point 2 (or User 2)to . . .24 Point 24NoNoNo19 Relay 1, Func 2Parameter1 Point 1 (or User 1)2 Point 2 (or User 2)to . . .24 Point 24NoNoNo20 Relay 2, Func 1Parameter1 Point 1 (or User 1)2 Point 2 (or User 2)to . . .24 Point 24NoNoNo21 Relay 2, Func 2Parameter1 Point 1 (or User 1)2 Point 2 (or User 2)to . . .24 Point 24NoNoNo