2000 Series | Program Entry Guide | 6.0 Open/Close EN | 24Bosch Security Systems | 7/05 | 35114FProgramExit Tone Yes to enable the exit delay toneand excursion tone.ProgramExit Tone No to disable the exit delay toneand excursion tone.5 No DelayDefault: Part OnSelection: Disabled, Part On, All On, All & Part0 Disabled1 Part On2 All On3 All & PartTheNo Delay prompt allows users to turn theirsystem on with No Entry or Exit Delay (instantarming). If this prompt is set to Part On, users can turntheir system Part On with No Delay by pressing the [0]key twice.If this prompt is set to All On, users can turn theirsystem All On with No Delay by pressing the [9] keytwice. If this prompt is set to All & Part, users can turntheir system All or Part On with No Delay.If this prompt is set to Disabled, users cannot turn theirsystem on with No Delay. Entry and exit delay arealways provided.Selecting Disabled for theNo Delay prompt alsodisables the Excursion feature. Refer to theExcursionprompt.6 ExcursionDefault: DisabledSelection: DisabledAll StepPart StepAll & Part StepAll ExitPart ExitAll & Part Exit0 Disabled1 All Step2 Part Step3 All & Part Step4 All Exit5 Part Exit6 All & Part ExitUse theExcursion prompt to configure the systemfor either the Step Outside or Exit User features.6.1 Step OutsideIf you enable the Step Outside feature, pressingthe [CLEAR] key at the keypad when the systemis on with No Delay starts the exit delay tone (ifExit Tone is programmed Yes) and bypasses allpoints programmed for delay (Digit 1 of pointcode = 6 or 8). The rest of the system remains on.The tone and bypass remain until the user pressesthe [CLEAR] key a second time, returning thesystem to its fully on state. If a point is faultedwhen the user presses the [CLEAR] key thesecond time, the tone and bypass continue. Theuser must either clear the fault (close the door) orturn the system off with a passcode.The Step Outside feature allows users to pick upthe morning paper or let the dog out withoutturning the system off.All Step: Only allows users access to the StepOutside feature when the system is All On withNo Delay (instant).Part Step: Only allows users access to the StepOutside feature when the system is Part On withNo Delay (instant).All & Part Step: Allows users access to the StepOutside feature when either All or Part of thesystem is On with No Delay (instant). PreviousNext |