2. ICMP functionality2.9 ICMP HDD status LEDsICMP HDD status LEDs54Image 2-8Status overview PWR/ERROR and READY LEDs:4 5HDD I/O RAID ICMP HDD StatusOff Off HDD idle / Disk in RAID OK.BlinkingGreenOff HDD I/O activity / Disk in RAID OK.BlinkingGreenBlinking Red HDD I/O activity / RAID rebuilding.Off Red HDD idle / Disk error. See troubleshooting table below for curativeactions.TroubleshootingSituation SolutionOne disk failed (red LED) + RAID degraded.The ongoing event is not interrupted.Note: The disk status (RAID degraded) can beretrieved via the (Web) Commander. See userguide of the (Web) Commander.1. Switch off the power.2. Replace the defect HDD with an original HDDspare part. See procedure "Removing a HDDfrom the ICMP", page 35, and "Installing aHDD into the ICMP", page 33. Ensure to insertthe HDD firmly.3. Switch on the power.Result: As soon the new HDD is detected by theICMP the rebuild of the RAID is started (Blinkingred LED).One disk failed (red LED) + Error 10580 “localstorage not available”.Note: The disk status (Error code) can beretrieved via the (Web) Commander. See userguide of the (Web) Commander.1. Switch off the power.2. Replace the defect HDD with an original HDDspare part. See procedure "Removing a HDDfrom the ICMP", page 35, and "Installing aHDD into the ICMP", page 33. Ensure to insertthe HDD firmly.3. Switch on the power.Result: As soon the new HDD is detected by theICMP the rebuild of the RAID is started (Blinkingred LED).22 R5905722 ICMP 09/11/2016