Page 2712-10Installation & Operation ManualQuick ReadThe Quick Read Feature allows you to read a ORION unit without having a route loaded. This is handy when you wish to verifythe installation of a unit, if you wish to verify that a unit is operating correctly, or if you wish to collect the reading and statusof a unit without loading a route.The Quick Read screen displays each reading received from an individual ORION endpoint or within range of ORIONendpoints. This screen also verifies proper ORION endpoint installation and can also be used to obtain final meter reads.1. Click the Quick Read button on the Main Menu, to view the following screen:Note: These readings cannot be transferred to the Reading Data Management Software.Figure 21: Quick Read2. To begin reading, select the desired reading technology, such as ORION and/or Permalog.Result: Readings from both types of devices are displayed.- To view all of the readings, move the slider bar up or down.