10values above 10 will display as zero values.Reviewing Statistical InformationOnce rundown torque values have been stored to memory, it is possible to view statistical values based on thoserundowns.To view statistical information:1. From either MEMORY MODE or RUN MODE press the MENU button.2. Press the UP menu scroll button until the Data Menu (3 of 3) item is displayed3. Press SEL to enter into the Data Menu area4. Press the UP menu scroll button until Display SPC Info 3 of 5) item is shown5. Press SEL to select and display Statistical Information for the set of data stored in the AUETA screen will display showing the following statistical values:n = number of rundowns stored into memoryX = mean torque value of all stored rundownsMin = the lowest stored torque valueMax = the highest stored torque valueTo disable MEMORY MODE, the user must clear the memory and enter RUN MODE. For instructions on howto clear memory, see Clear Memory (3-4, 3-5) on page XXAUET MENU FUNCTIONSThe basic set-up features of the AUET are accessed through the MENU function. Data management, system set-up,display characteristics and power management can all be configured from this area to match the users’ needs.Accessing the MENU Functions1. Turn the AUET On2. The MENU structure is accessed by press the Left Selection button directly under the displayed MENUon the screen.From this screen the SELECTION ARROW buttons can be used to access the individual menu options. By pressingthe button, the menu options will display in the following order: