Appendix D: Using the AFU for DOS ● 73UPDATEThe UPDATE command updates a HostRAID controller’s flash components from the flashimage data in a UFI file. You can use the UPDATE command to update a single HostRAIDcontroller’s flash components or to update multiple HostRAID controllers on your computer.You must restart the computer following an UPDATE command.Command SyntaxThe command syntax for the UPDATE command is as follows:AFU UPDATE [/C<Controller ID>] [/D <UFI File Path>]Command SwitchesFor details on the /C and /D switches, see SAVE on page 72.ExamplesThe following example shows a typical system response after an update has been performed:A:\> AFU UPDATE /C 0Adaptec Flash Utility V1.0-0 B1406(c)Adaptec Inc. 1999–2005. All Rights Reserved.Updating Controller 0 (Adaptec ASC-48300)Reading flash image file (Build 1406)AFU is about to update firmware on controller(s) Adaptec ASC-48300***PLEASE DO NOT REBOOT THE SYSTEM DURING THE UPDATE***This might take a few minutes.Writing Adaptec ASC-48300 (4MB) Flash Image to controller 0...OK.Verifying...OKPlease restart the computer to allow firmware changes to take effect.VERIFYThe VERIFY command compares the contents of each of the flash components on a HostRAIDcontroller to the corresponding image in a UFI file and indicates whether they match. Use thiscommand to determine whether a HostRAID controller’s flash components are up-to-datewhen compared to a specific UFI file.Command SyntaxThe command syntax for the VERIFY command is as follows:AFU VERIFY [/C<Controller ID>] [/D <UFI File Path>]Command SwitchesFor details on the /C and /D switches, see SAVE on page 72.