FPC 8084 User¶s Manualnumber1. For the first time installation, or changing PenMount TouchScreen’s COM port, use PMDETECT (e.g.C:\PENMOUNT\PMDETECT) to check the COM port and IRQnumber. PMDETECT will save the correct data to PMOUSE.CFGfile for further use.The driver detects your communication COM port and IRQ numberfrom COM1 IRQ4, COM2 IRQ3, COM3…. to COM4 IRQ15.PenMount driver can find the COM port and IRQ numberautomatically. The screen will then show:PenMount is initialized successfully!!!Create file “pmouse.cfg”. Success.PenMount internal settings:Comm. Port: COM IRQ..........1. PMDETECT program is able to skip the IRQ number detecting ifyou Touchscreen Driver Installation 13 do not need to detect thespecified IRQ number. For example, you do not need to detectIRQ5, and the command is:C:\PENMOUNT\PMDETECT -N5If you do not need to detect IRQ5 and IRQ9, the command is:C:\PENMOUNT\PMDETECT -N5 -N93.2.3.3 Do Calibration1. To adjust the touch screen mapping properly to display screen,use PM.BAT (C:\PENMOUNT\PM) to do calibration. Choose “1”DO CALIBRATION (adjust screen mapping).2. The message on screen asks you to select video mode number.Selectby keyboard to start the calibration, touch the upper-center point, then28