Ablerex GR 650 User Manual
Contents |
2REPLACING THE BATTERYNote:Once the battery is disconnected, the loads are not protectedfrom power outages.1. Use a cross-type screwdriver to remove the four screws from bottomshell.2. Take-up top cover and battery cover.3. Loosen the black wire from the negative (-) terminal and red wire fromthe positive (+)4. terminal.5. Connect the battery leads to the new battery.6. Note: Small sparks at the battery connectors are normal during connection.7. Slide the battery into the UPS.8. Close the front panel and fasten two screws.9. Dispose of the old battery properly at an appropriate recycling facility.TROUBLE SHOOTINGShould the UPS fail to function correctly werecommend you perform the following testsbefore calling the service.Check step:Step 1: Is the main switch in the “ON” position?Step 2: Is the UPS plugged into the mainspower supply?Step 3: Does the power supply fall withinspecified unit values?Step 4: Has the fuse gone in the mains plug?Step 5: Is the UPS overload?Step 6: Is the battery flat or defective?Situation Check Items SolutionNo LED display on the frontpanel.Low battery. Charge the UPS at least 6 hours.Battery fault. Replace the battery with the same type of battery.The UPS is not turned on. Press the power switch again to turn on the UPS.Alarm continuously soundswhen the Utility is normal.The UPS is overload. Remove some loads first. Before reconnecting equipment, please verifythat the load matches the UPS capability specified in the specs.When power fails, back up timeis shorten.The UPS is overload. Remove some critical load.Battery voltage is too low. Charge the UPS at least6 hours.Battery defect. It might be due to hightemperature operation environment, or improperoperation to battery.Replace the battery with the same type of battery.The Utility is normal but LED isflashing.Power cord is loose. Reconnect the power cord properly.GR 450 / 650 / 850 SPECIFICATIONS GR 1000 / 1500 / 2000 SPECIFICATIONSModel GR 450 GR 650 GR 850 GR 1000 GR 1500 GR 2000Capacity 450VA/270W 650VA/380W 850VA/500W 1000VA/600W 1500VA/900W 2000VA/1200WInputVoltage 220/230/240VACVoltage range 160~290VacOutputVoltage Regulation +/- 10%Waveform Simulated Sine WaveBatteryType & Number 12V/5Ah x 1 12V/7Ah x 1 12V/9Ah x 1 12V/7Ah x 2 12V/7Ah x 2 12V/9Ah x 2Charging time 4-6 hours recover to 90% capacityPhysicalDimension(DxWxH, mm) 292 x 100 x 140 315 x 148 x 198Net Weight(kgs) 4 5 5.5 9 10.5 11.8Packaging Dimension(DxWxH,mm) 321 x 137 x 226 411 x 229 x 302Gross Weight(kgs) 4.5 5.5 6 10 11.5 12.8EnvironmentHumidity 0-90 % RH @ 0-40 C (non-condensing)Noise level Less than 40 dBSafetySecurity certificate CEGR-450/650/850GR-1000/1500/2000STEP1STEP2STEP1STEP2 |
Related manuals for Ablerex GR 1000
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved