Network Turnup Procedure Total Access 600 Series System Manual36 © 2004 ADTRAN, Inc. 61200624L1-1B1. INTRODUCTIONThis section discusses Total Access 600 Series installation.2. TOOLS REQUIREDThe tools required for wallmount installation of the unit are:• Four #8 x 3/4 inch pan-head wood screws• Drill and drill bit set• Flat head screwdriver (medium)• Two Phillips head screwdrivers (small/medium)• Wire-wrap gun (optional)• 25-pair male amphenol cable (customer connection)• Selected punch-down block and tool3. UNPACK AND INSPECT THE SYSTEMEach unit is shipped in its own cardboard shipping carton. Open each carton carefully and avoid deeppenetration into the carton with sharp objects.After unpacking the unit, inspect it for possible shipping damage. If the equipment has been damaged intransit, immediately file a claim with the carrier, and then contact ADTRAN Customer Service (seeCustomer Service, Product Support Information, and Training in the front of this manual).To prevent electrical shock, do not install equipment in a wet location or during alightning storm.During installation, power should be the last connection made.Electronic equipment can be damaged by static electrical discharge. Before handlingmodules, put on an antistatic discharge wrist strap to prevent damage to electroniccomponents. Place equipment in antistatic packing material when transporting or storing.When working on equipment, always place it on an approved antistatic mat that iselectrically grounded.