ADT TSSC-BASE User Manual
– 5 –CHIME MODEYour system can be set to alert you to the opening of a door or window while it is disarmed by using CHIMEmode. When activated, three tones sound at the Keypad whenever a protected perimeter door or window isopened, and the “Not Ready” message is displayed. Pressing the READY [*] key displays the open protectionpoints.Note that Chime mode can be activated only when the system is disarmed.1. To turn Chime Mode on, enter the security code and press the CHIME key [9].2. To turn Chime Mode off, enter the security code and press the CHIME key again.KEYPAD TONESWhen the Keypad is generating a periodic beep (once per minute), pressing the [*] key provides moreinformation.When the system is armed and there is a trouble condition, the Keypad displays “Device Trouble”. Pressingthe [*] key provides more information.QUICK EXITTo start Quick Exit when enabled.Stay Mode – Enter User code + STAY key.Instant Mode – Enter User code + INSTANT keyNight-Stay Mode – With the system armed in Night-Stay Mode and the exit delay expired,enter User code + STAY key + STAY key.HOST CHECK-INIf Host Check-In interval is set to 200 seconds, “Download Com/Upload Completed” message is displayed atthe Keypad every 200 seconds.TEST MODEUse Test mode to check each protection point for proper operation.Testing should be conducted weekly to ensure proper operation.1. Disarm the system and close all protected windows, doors, etc.2. Enter the Master code + [5] (TEST), then press 1.3. Listen. The external sounder should sound for about 1 second then turn off.4. Fault all zones in turn and listen for three beeps from the keypad. ID of each faulted point should appearon the keypad display. The display clears when the zone is closed. Note that if wireless motion detectorsare used, there is a 3-minute delay between activations. This conserves battery life.5. Test all smoke and CO detectors following the manufacturer's instructions and check the display.6. When all zones have been checked and are intact (closed), there should be no zone identificationnumbers displayed on the keypad.7. Exit test mode: security code + [1] (OFF).NOTES:• The keypad sounds a single beep about every 60 seconds as a reminder that the system is in the Testmode.• Alarm messages are not sent to your Central Station while Test mode is on.• If a problem is experienced with any protection point (no confirming sounds, no display), call for serviceimmediately.• If the test mode is inadvertently left active, it automatically turns off after 30 minutes. During the finalfive minutes, the keypad will emit a double beep every 30 seconds. |
Related manuals for ADT TSSC-BASE
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved