– 34 –01 LED #00Enter the LED number on the FSA module (01-08 for FSA-8; 01-24 for FSA-24).Press [Q] to continue.The keypad will display the Start and Stop summary screens again.Press [Q] to continue.When all output devices have been programmed, enter 00 at the "ENTER OUTPUT #." prompt.If defining a zone list, continue to the next section. If not, enter 00 + [Q] at the next two prompts. You will then be asked "QuitMenu Mode?" Enter 1 for "Yes," 0 for "No." Then enter Q99 to exit programming completely.If supervision of the 4204CF Relay Output is desired, enter a response type for that output's corresponding supervisory zone.This is equal to 600 + [Relay ID No.]. For example, if you are programming Relay ID No. 1, the relay's supervisory zonewould be 601. Program this zone for response type 05 (Day/Night) inZone Programming.Zone List ProgrammingAfter all Outputs have been programmed, upon entering 00 at the "ENTER OUTPUT #." prompt, you will be asked to enter azone list. If a zone list number was used to start or stop a Output, you must define the zones belonging to that list as follows:ENTER Zn LIST ?00=QUIT 00Enter the zone list number 01-15. Enter 00 to quit.01 ADD ZONE #000=QUIT 000Using 3-digit entries, enter each zone to be included in this zone list. Press [∗] after each zonenumber is entered.When all zones have been entered, enter 000.Press [Q] to continue.01 Del Zn LIST ?1=YES 0=NO 0Enter 0 to save the zone list entered. Enter 1 to delete that zone list.01 DEL ZONES ?1=YES 0=NO 0Enter 1 to delete one or more zones in that zone list. Enter 0 if no changes are necessary. If 1is entered, the following screen will appear, otherwise the "Enter Zone LIST" prompt willreappear.01 Zn to DELETE ?000=QUIT 000Enter each zone number to be deleted from the zone list, pressing [Q] after each number.VIEW Zn LIST ?00=QUIT 00This will appear if 00 is pressed at the “Enter Zone LIST” prompt. Enter the zone list numberthat you wish to view.Press [Q] to continue.01 ASSIGNED ZONE000=QUIT 000Press [Q] to scroll through all zones in that list. Enter 000 +[Q]to quit.Press [1] to exit Menu Mode.Press Q99 to exit Program Mode.Relay Voice DescriptorsIf using the 4285/4286 VIP Module, voice descriptors can be programmed for outputs 1-16 (even though the system has 96outputs, only 1-16 can have a Relay Voice Descriptor programmed). These descriptors will be announced by the voicemodule when accessing the Outputs via the # 70 Relay Access Mode via telephone.Each voice descriptor can consist of up to three words selected from the Relay Voice Descriptors and Custom WordSubstitutes Vocabulary list (later in this section).The index numbers from this vocabulary list are to be used for relay voice descriptors only. For normalsystem voice annunciation (e.g., alarms, troubles, status), use the highlighted words in the alpha vocabularylist in theAlpha Programming part of this guide.To enter relay voice descriptors, do the following:1. From Data Field Programming Mode, press #93 to display the "ZONE PROG?" prompt.2. Press 0 (NO) to each menu option until the "RLY VOICE DESCR?" prompt is displayed. Follow the instructions below.While in this mode, press [Q] to advance to next screen. Press [#] to back up to previous screen.www.PDF-Zoo.com