WFR113539 - 13 www.adclaundry.com 23Heat Input / Gas Consumption / Orifice (Injector) DataShaded areas are stated in metric equivalents* Gas valve’s internal regulator disabled.** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.The input ratings shown on the rating plate are for elevationsup to 2,000 feet (610 meters), unless elevation requirementsof over 2,000 feet (610 meters) were specified at the time thedryer order was placed with the factory. The adjustment orconversion of dryers in the field for elevations over 2,000 feet(610 meters) is made by changing each burner orifice. If thisconversion is necessary, contact the reseller who sold thedryer or contact the manufacturer.IMPORTANT: If connection to this appliance is made with aflexible hose, it must be suitable for the appliance categoryin accordance with national installation regulations of thecountry of destination, and if in doubt the installer mustcontact the supplier. The manufacturer of this appliancedoes not recommend the use of flexible gas supply line/hose. An external gas supply shutoff must be provided.CE DryersThere is an N.P.T. to B.S.P.T. adaptor installed on dryers beingshipped to CE countries.! WARNINGThe dryer must be restrained to prevent straining thegas connection if the dryer is moved while the gassupply is still connected. Holes for the attachment ofa restraining device are provided in the top of thedryer. The length and design of the restraint shouldbe as necessary to prevent strain on the gas line ifthe dryer is moved.If the dryer is to be moved then the following stepsmust be taken:• Disconnect electrical power to the dryer.• Close all external gas supply shutoff valves.• Disconnect the gas supply line.• Remove the restraint from the dryer.IMPORTANT: Pipe joint compounds that resist the action ofnatural, propane, and butane gases must be used.NOTES _________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________GAS SPECIFICATIONS FOR DRYERS GOING TO REST OF THE WORLD**Model GasTypeNominalHeating ValueSupplyPressure Gross Heat Input Orifice Size Orifice(Injector)QuantityBurnerPressureB tu /ft 3 in WC Btu/hr kW DMS mm in WCAD-35i Natural 1,000 7.0-13.0 70,000 20.5 22 3.988 1 3.5*Propane 2,500 11.0 70,000 20.5 41 2.438 1 10.5AD-50i Natural 1,000 7.0-13.0 125,000 36.64 5 5.22 1 3.5*Propane 2,500 11.0 125,000 36.64 30 3.264 1 10.5AD-80i Natural 1,000 7.0-13.0 135,000 39.53 2 5.613 1 3.5*Propane 2,500 11.0 135,000 39.53 29 3.454 1 10.5