20 American Dryer Corp. WFR113539 - 13For 110V ApplicationsSINGLE-PHASE ELECTRICAL LEAD CONNECTIONSBlack+Positiveor L1White or Red+Neutralor L2Green+GroundFor 208-240V ApplicationsIMPORTANT: For personal safety and proper operation, thedryer must be grounded.Provisions are made for ground connection in each dryer atthe electrical service connection area.Electrical ConnectionsA wiring diagram is located behind the control panel forconnection data.If local codes permit, power to the dryer can be made by theuse of a flexible UL listed power cord/pigtail (wire size mustconform to rating of dryer), or the dryer can be hard wireddirectly to the service breaker panel. In both cases, a strainrelief must be installed where the wiring enters the dryer.VFD GFCI Ground TripDryers that are going to Europe may require to remove theEMC from the VFD due to the GFI. If VFD is tripping due toGFI, remove the EMC. Any electrical work that is requiredmust be done by a certified technician or a licensed electrician.For CE Models OnlyThe means for disconnection from the supply must beincorporated into wiring having a minimum contact separationof 3.0mm in all poles.Single-Phase (1ø) Gas and SteamWiring Connections / HookupThe electrical input connections on all single-phase (1ø) gasdryers and steam dryers are made into the rear service boxlocated at the upper left area of the dryer.