Ferroresonant L-828/L-829 CCR Installation 2009 ADB Airfield Solutions, Incorporated 96A0288T 3-3All rights reserved Issued 9/048. Engage main circuit breaker or disconnect switch to energize theregulator.9. Turn front panel rotary selector switch to all brightness steps, andverify that current values on the panel ammeter correspond to those inTable 2-9 for each brightness step.10. Disengage the main current breaker or disconnect switch to de-energize the regulator.11. Turn the rotary selector switch to OFF.12. Connect remote control lines, if required, to remote control terminalblock TB1. Use AWG 19, 300 V wire or larger as indicated in Table3-3 for 120 Vac signals. See Figure 8-1 in the Wiring Schematicssection for remote control connections.NOTE: If the ADB Airfield Solutions Advanced Control Equipmentis used with the ferroresonant L-828 CCR, refer to the AdvancedControl Equipment manual (96A0245) for wiring connections toremote control.NOTE: Tables 3-1 through 3-3 provide the necessary connections forremote control. Terminal B1 (B10) does not need to be wired.Brightness step B1 (B10) occurs when the regulator is switched on.Table 3-1 Remote 120 Vac Control Connections (3-Step/6.6 A)For this remote intensity step… Connect CCI to…LOW (4.8 A) CCMEDIUM (5.5 A) CC, B30HIGH (6.6 A) CC, B100OFF Not applicableTable 3-2 Remote 120 Vac Control Connections (5-Step/6.6 A)For this remote intensity step… Connect CCI to…2.8 A CC3.4 A CC, B24.1 A CC, B35.2 A CC, B46.6 A CC, B5OFF Not applicableWiring Connections andStartup (contd.)