25-62-30 Page 27 of 88APR 06/10COBHAM AVIONICS WULFSBERG ELECTRONICSABBREVIATED COMPONENT MAINTENANCE MANUALME406 (453-6603), ME406HM (453-6604)(2) The cockpit-mounted remote switch assembly is comprised of an ELT status LED and controlswitch, and allows an operator to manually turn the ELT on (i.e., activate) for testing andreset (i.e., deactivate) the ELT. See "Figure 3. Remote Switch Front View".NOTE: The ELT CANNOT be disarmed or disabled from the cockpit. Cockpit operation islimited to deactivating or manually activating the ELT.Figure 3. Remote Switch Front View(3) The buzzer (i.e., horn) provides an audible alert when the ELT is active. See "Figure 4.Buzzer".Figure 4. Buzzer(4) The battery pack for the ME406 Series ELT consists of two “D” size lithium manganese dioxidecells connected in series. To prevent the cells from being charged, diodes are connectedacross each cell and fuses are connected to the output. See "Figure 5. Battery PackAssembly".Figure 5. Battery Pack AssemblyARTEXONARMPress ONWait 1 SecondPress ARMEMERGENCY USE ONLYTest/ResetELTLEDSWITCH