2101510 Rev. AG Page 2–29• Detector Noise Values• Detector Balance Values2.13.5 Audit Logs• Last 100 alarms• Last 100 events2.14 TCR Sample Probe (Optional Equipment)The temperature compensated regulator (TCR) sample probe is used to capturenatural gas from the pipe line for NGC analysis. To capture the gas sample, it isrecommended the TCR sample probe be mounted horizontally. It can be mountedvertically if this is more suitable to the installation.TCR sample probe is specifically selected for operation with the NGC. The designof the probe prevents icing without the need for electrical power.It is the customer’s responsibility to install and weld a 3/4 –inchfemale NPT standard pipeline coupling on the main meter rungas flow pipe. This coupling allows installation of the TCRsample probe.Check Table 2–9 to ensure the correct sample probe for installation. The length ofthe sample probe is dependent on the diameter of the meter run.ABB Totalflow recommends that a TCR be installed with the NGC. Refer to Figure2-19.Read the installation instructions in Chapter 2 to develop apipeline installation plan prior to actual installation.Table 2–9 Optional Temperature Compensated Regulator (TCR)Length(inches) Description4 Temperature Compensated Sample Probe/Regulator/Relief Valve8 Temperature Compensated Sample Probe/Regulator/Relief ValveFigure 2-19 Temperature Compensated Regulator With Sample Probe3/4" NPTGAS FLOWSAMPLE PROBECUSTOMER INSTALLED COUPLINGPRESSURE GAUGEOUTLET PORT 1/4" NPTRELIEF VALVE