Toshiba TOSVERT VF-PS1 manuals
TOSVERT VF-PS1
Table of contents
TOSVERT VF-PS1
Table of contents
- safety precautions
- notes on use
- Table Of Contents
- OVERVIEW
- EXTERIOR FEATURES
- DeviceNet indicator
- INSTALLING THE DEV002Z
- CONNECTING TO THE NETWORK
- Network Grounding
- Setting a MAC ID number and a network baud rate
- COMMUNICATIONS-RELATED PARAMETERS
- f851: Communication Loss Action Setting (Network breaks)
- f830: Assembly Object Setting
- DEVICENET LOCAL/REMOTE OPERATION
- SPECIFICATIONS
TOSVERT VF-PS1
Table of contents
- Table Of Contents
- Introduction
- Exterior features
- PDP002Z Device Data
- Setting a station address
- Status indicator
- PPO TYPE
- STW Control Word Data
- ZSW Status Word Data
- State Macine
- Examples of driving by the State Machine
- The Access to the PROFIBUS parameter
- Examples of reading or changing the PROFIdrive parameter
- Access to the VF-AS1/PS1 parameter
- USER DEFIND" Profile
- The overview of the VF-AS1/PS1 parameter
- FA07 (Frequency reference from internal option PCB)
- FD01 (Inverter status (real time))
- FE36 (Analog input value VI/II)
- FC91 (Alarm code)
- FC90, FE10 - FE13 (Inverter fault)
- About GSD file
TOSVERT VF-PS1
Table of contents
- safety precautions
- INTRODUCTION
- NAMES OF THE PARTS ON THE BOARD
- CONNECTION TO THE INVERTER
- Wiring
- FUNCTIONAL DESCRIPTION
- Selection of encoder type
- Vector control setting parameter
- Monitoring method for feedback amount
- Confirmation of PG's rotational direction
- Speed abnormality detect function
- Stop position control function (VF-AS1 only)
- Pulse input command (speed command selection)
- Pulse input setting parameter
- EXTERNAL VIEW
- SPECIFICATION
- OPTION CABLE
- WARRANTY
TOSVERT VF-PS1
Table of contents
- Table Of Contents
- Introduction
- PID control function
- Speed PID control
- Dancer control
- PID control type and parameters
- Setting for PID control
- Process value
- Override function
- Set to suit the system
- Switch to frequency command operation
- PID control adjustment
- Proportional (P) gain
- Applied adjustment (Common)
- Applied adjustment (for speed PID control)
- Analog input characteristics
- Parameter list of PID control
TOSVERT VF-PS1
Table of contents
- Table Of Contents
- Table Of Contents
- OVERVIEW
- RJ45 connector pin layout
- LED indicator
- PARAMETERS
- The details of the parameter setting
- Assigning IP addresses (f576-f588)
- Command data (f831-f838), Monitor data (f841-f848)
- FA06 (Command word 1)
- FA23 (Command word 2)
- FA07 (Frequency reference from comunciation option)
- FD01 (Inverter status (real time))
- FD03 (Output current (real time))
- FC91 (Alarm code)
- OBJECTS
- Identity Object (01 hex)
- Message Router Object (02 hex)
- Assembly Object (04 hex)
- Connection Manager Object (06 hex)
- Motor Data Object (28 hex)
- Control Supervisor Object (29 hex)
- Run/Stop Event Matrix
- AC/DC Drive Object (2A hex)
- Application Objects (64 hex)
- Port Object (F4 hex)
- TCP/IP interface (F5 hex)
- Ethernet link (F6 hex)
- CONFIGURATION OF THE ASSEMBLIES
- Instance 20: CIP basic speed control output
- Instance 21: CIP extended speed control output
- Instance 22: CIP speed and torque control output
- Instance 100 : Native drive output
- Instance 101: Native drive output
- Instance 102: Native drive output
- Instance 103: Allen Bradley Drive Profile Output
- Instance 104: Allen Bradley Drive Profile Input
- ABOUT EDS-FILE
- UNUSUAL DIAGNOSIS
TOSVERT VF-PS1
Table of contents
- instruction manual
- safety precautions
- general operation
- maintenance and inspection
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- read first
- structure of the main body
- detaching the cover
- grounding capacitor switching method
- installing the dc reactor
- notes on the application
- what to do about the leak current
- connection equipment
- standard connections
- description of terminals
- control circuit terminal block
- serial rs485 communication connector
- setting/monitor modes
- simplified operation of the vf-ps
- frequency setting
- panel operation
- searching and setting parameters
- how to set parameters
- setting parameters in the standard setting mode
- functions useful in searching for a parameter or changing a parameter setting
- basic parameters
- setting acceleration/deceleration time
- manually setting acceleration/deceleration time
- setting parameters by operating method
- selection of operation mode
- selecting control mode
- manual torque boost–increasing torque boost at low speeds
- maximum frequency
- setting frequency command characteristics
- selecting forward and reverse runs (operation panel only)
- setting the electronic thermal
- changing the display unit % to a (ampere)/v (volt)
- meter setting and adjustment
- pwm carrier frequency
- dynamic (regenerative) braking - for abrupt motor stop
- standard default setting
- searching for all reset parameters and changing their settings
- easy key function
- extended parameters
- putting out signals of arbitrary frequencies
- input signal selection
- assigning priority to the terminal board in the operation panel and operation mode
- analog input signal switching
- terminal function selection
- modifying output terminal functions
- v/f 5-point setting
- operation frequency
- start frequency/stop frequency
- frequency setting signal 0hz dead zone handling function
- motor shaft fixing control
- function of issuing a 0hz command during a halt
- jog run mode
- setting frequency via external contact input (up/down frequency setting)
- jump frequency - jumping resonant frequencies
- preset speed operation frequencies
- bumpless operation
- retry function
- avoiding overvoltage tripping
- reverse run prohibition
- commercial power/inverter switching
- pid control
- setting motor constants
- increasing the motor output torque further in low speed range
- torque limit
- speed control gain
- operating a synchronous motor
- protection functions
- emergency stop
- output phase failure detection
- control mode for low current
- detection of output short circuit
- cooling fan control selection
- abnormal speed detection
- vi/ii analog input wire breakage detection level
- rush current suppression relay activation time
- selection of a restart condition for the motor stopped with a mechanical brake
- motor ptc thermal protection
- forced fire-speed control function
- low torque detection signals
- adjustment parameters
- setting of optional meter outputs
- operation panel parameter
- displaying the rotational speed of the motor or the line speed
- changing the steps in which the value displayed changes
- changing the standard monitor display
- integrating wattmeter
- communication function
- open network option
- instruction manuals for optionally available devices and special functions
- operation with external signal
- applied operation with input and output signals (operation by terminal board)
- functions of output terminals (incase of sink logic)
- analog input filter
- setup of external speed command (analog signal)
- setup by analog input signals (rr/s4 terminal)
- setup by analog input signals (vi/ii terminal)
- setup by analog input signals (rx terminal)
- monitoring the operation status
- monitoring the status
- display of detailed information on a past trip
- changing status monitor function
- display of trip information
- monitor display at tripping
- display of alarm, pre-alarm, etc
- measures to satisfy the standards
- measures to satisfy the emc directive
- low-voltage directive
- measures to be taken to satisfy the ul/csa standards
- caution as to the protection of motors from overload
- compliance with safety standards
- selection of peripheral devices
- installation of a magnetic contactor
- application and functions of options
- optional internal devices
- connection of a dc power supply and other electric units
- models and their standard specifications
- outside dimensions and weight
- outline drawing
- trip causes/warnings and remedies
- method of resetting causes of trip
- if the motor does not run while no trip message is displayed
- how to check other troubles
- inspection and maintenance
- periodical inspection
- making a call for servicing
- disposal of the inverter
TOSVERT VF-PS1
Table of contents
- instruction manual
- Instruction Manual
- Connection
- Operations
- List of function
- detaching the cover
- grounding capacitor switching method
- installation environment
- cautions on wiring
- standard connections
- description of terminals
- searching and setting parameters
- monitoring the operation status
- measures to satisfy the standards
- caution as to peripheral devices
- selection of peripheral devices
- selection of wiring equipment
- table of parameters
- specifications
- outside dimensions and mass
TOSVERT VF-PS1
Table of contents
- I. Safety precautions
- general operation
- maintenance and inspection
- I I. Introduction
- read first
- names and functions
- notes on the application
- cautions on wiring
- standard connections
- description of terminals
- panel operation
- how to set parameters
- selection of operation mode
- selecting control mode
- sensorless vector control
- setting the electronic thermal
- meter setting and adjustment
- standard default setting
- default setting
- extended parameters
- input signal selection
- terminal function selection
- frequency priority selection
- retry function
- pid control
- protection functions
- adjustment parameters
- operation panel parameter
- communication function
- display of trip information
- selection of peripheral devices
- installation of a magnetic contactor
- specifications
- outline drawing
- before making a service call
- if the motor does not run while no trip message is displayed
- inspection and maintenance
- periodical inspection
- making a call for servicing
- disposal of the inverter
TOSVERT VF-PS1
Table of contents
- safety precautions
- general operation
- maintenance and inspection
- Read first
- structure of the main body
- detaching the cover
- grounding capacitor switching method
- Connection
- installing the dc reactor
- Operations
- what to do about the leak current
- installation environment
- cautions on wiring
- standard connections
- description of terminals
- control circuit terminal block
- Basic parameters
- Extended parameters
- searching and setting parameters
- how to set parameters
- setting parameters in the standard setting mode
- increasing starting torque
- setting parameters by operating method
- Operation with
- selecting control mode
- maximum frequency
- setting frequency command characteristics
- setting the electronic thermal
- Monitoring the
- pwm carrier frequency
- standard default setting
- searching for all reset parameters and changing their settings
- easy key function
- input signal selection
- terminal function selection
- speed command switching
- operation frequency
- function of issuing a 0hz command during a halt
- jog run mode
- preset speed operation frequencies
- reverse run prohibition
- pid control
- increasing the motor output torque further in low speed range
- torque limit
- current and speed control gain
- fine adjustment of frequency setting signal
- operating a synchronous motor
- protection functions
- output phase failure detection
- detection of output short circuit
- abnormal speed detection
- guide to time of replacement
- selection of a restart condition for the motor stopped with a mechanical brake
- adjustment parameters
- operation panel parameter
- tracing functions
- integrating wattmeter
- communication function
- instruction manuals for optionally available devices and special functions
- operation with external signal
- monitoring the operation status
- monitoring the status
- display of detailed information on a past trip
- changing status monitor function
- display of trip information
- monitor display at tripping
- measures to satisfy the standards
- caution in installing the inverter
- caution as to the protection of motors from overload
- compliance with safety standards
- selection of peripheral devices
- installation of a magnetic contactor
- application and functions of options
- optional internal devices
- connection of a dc power supply and other electric units
- specifications
- outline drawing
- before making a service call
- method of resetting causes of trip
- if the motor does not run while no trip message is displayed
- how to check other troubles
- inspection and maintenance
- periodical inspection
- making a call for servicing
- disposal of the inverter
TOSVERT VF-PS1
Table of contents
- Table Of Contents
- INTRODUCTION
- NAMES AND FUNCTIONS OF MAIN PARTS
- LED indicator
- Setting a station address
- PARAMETERS
- FUNCTIONAL PROFILE
- Synch Time Command
- Analog Input Object
- Analog Input Attribute
- Analog Input COS Works
- Binary Input Object
- Binary Input Attribute
- Analog Output Object
- Analog Output Attribute
- Binary Output Object
- Binary Output Attribute
- Error Message Format
- VF-PS1 Parameter access
- VF-PS1 TRIP CODE
- SPECIFICATIONS