OneStart

AAON RN Series manuals

RN Series first page preview

RN Series

Brand: AAON | Category: Heat Pump
Table of contents
  1. Safety
  2. RN Series Feature String Nomenclature
  3. General Information
  4. Receiving Unit
  5. Packaged Direct Expansion (DX) Units
  6. Gas or Electric Heating
  7. Wiring Diagrams
  8. Installation
  9. Setting the Curb
  10. Figure 5 - RN Series 6-8 and 10 ton Unit Gasket Locations
  11. Figure 6 - RN Series 9 and 11-15 ton Unit Gasket Locations
  12. Figure 7 - RN Series 16-25 and 30 ton Unit Gasket Locations
  13. Figure 8 - RN Series 26, 31-50, 60, and 70 ton Unit Gasket Locations
  14. Forklifting the Unit (6-25 and 30 ton)
  15. Figure 10 - Lifting Details of a 6-25 and 30 ton Standard or Power Exhaust Unit
  16. Figure 12 - Lifting Details of a 26, 31-50, 60 and 70 ton Unit
  17. Duct Connection
  18. Seismic Curb Installation
  19. Figure 16 - Seismic Solid Bottom Curb without Filters Cross Section
  20. Figure 19 - Seismic Rigid Mount Curb
  21. Figure 20 - 90-140 ton Condenser Coil Guard Installation Instructions 1
  22. Outside Air Rain Hood
  23. End Flashing Installation
  24. Metal Mesh Filters (6-25 and 30 ton Units)
  25. Electrical
  26. Variable Speed Compressors
  27. Gas Heating
  28. Piping Sizing Examples
  29. Inlet and Manifold Pressures
  30. Leak Testing
  31. Refrigerant-to-Water Heat Exchanger
  32. Freezing Water in the Heat Exchanger
  33. Water Piping
  34. Table 18 - Standard Brazed Plate Heat Exchanger Water Connections
  35. Condensate Drain Piping
  36. Heating Coils
  37. Electric Preheat
  38. System Setting Screens
  39. Table 23 - Stages of Electric Preheat
  40. LED Flash Alarm Codes
  41. Energy Recovery Units
  42. Startup
  43. Power Return Axial Flow Fans (16-25 and 30 tons)
  44. Figure 34 - Fan with the HUB on the Top and RET on the Bottom
  45. Power Return and Exhaust Axial Flow Fans (26 and 31-140 tons)
  46. Filters
  47. Checking Liquid Sub-Cooling
  48. Adjusting Sub-cooling and Superheat Temperatures
  49. Table 27 - R-410A and R-22 Refrigerant Temperature-Pressure Chart
  50. Gas Heater Instructions
  51. Condenser Fan Electronically Commutated Motor (ECM) Startup
  52. VFD Controlled Condenser Fan Startup
  53. Operation
  54. Electric Heating Operation
  55. Maintenance
  56. Gas Heat Exchanger Removal
  57. Condensate Drain Pans
  58. Evaporator Coil (6-25 and 30 ton)
  59. E-Coated Coil Cleaning
  60. Microchannel Coil Cleaning
  61. Supply Fans
  62. Phase and Brownout Protection
  63. Variable Capacity Compressor Controller
  64. Filter Replacement
  65. Table 30 - 6-8 and 10 ton Pre Filters
  66. Table 34 - 50, 60, and 70 ton Pre Filters
  67. Table 37 - 26, 31-50, 60, and 70 ton Preheat Filters
  68. Table 40 - 13 and 15 ton Unit Filters
  69. Table 42 - 26, 31, and 40 ton Unit Filters
  70. Table 45 - 90-140 ton Unit Filters
  71. Table 49 - 26, 31-50, 60, and 70 ton Energy Recovery Wheel Filters
  72. Replacement Parts
  73. Appendix A - Heat Exchanger Corrosion Resistance
  74. Appendix B - Thermistor Temperature vs. Resistance Values
  75. RN Series Startup Form
  76. Maintenance Log
  77. Literature Change History
RN Series first page preview

RN Series

Brand: AAON | Category: Heat Pump
Table of contents
  1. Table Of Contents
  2. Table Of Contents
  3. Table Of Contents
  4. Table Of Contents
  5. Safety
  6. rn series feature string nomenclature
  7. general information
  8. Receiving Unit
  9. Packaged Direct Expansion (DX) Units
  10. Gas or Electric Heating
  11. Wiring Diagrams
  12. Setting the Curb
  13. Forklifting the Unit (11, 13 and 16-30 ton)
  14. Figure 4 - Lifting Details of a 11, 13 and 16-30 ton tons ton Standard or Power Exhaust Unit
  15. Duct Connection
  16. Figure 6 - Duct Connection
  17. Outside Air Rain Hood
  18. Metal Mesh Filters (11, 13 and 16-30 ton)
  19. Figure 10 - Unit Utility Entry
  20. Thermostat Control Wiring
  21. Gas Heating
  22. Table 6 - Propane (kBtu/hr) Maximum Piping Capacities
  23. Piping Sizing Examples
  24. Additional Gas Piping Considerations
  25. Leak Testing
  26. Open Loop Applications
  27. Freezing Water in the Heat Exchanger
  28. Table 9 - Standard Brazed Plate Heat Exchanger Water Connections
  29. Condensate Drain Piping
  30. Draw-Through Coils
  31. Heating Coils
  32. Electric Preheat
  33. System Setting Screens
  34. Table 15 - Stages of Electric Preheat
  35. LED Flash Alarm Codes
  36. Energy Recovery Units
  37. Startup
  38. Table 16 - Plenum Fan Set Screw Specifications
  39. Power Return Axial Flow Fans (16-25 and 30 tons)
  40. Figure 19 - Bushing Mount Location
  41. Filters
  42. Adjusting Refrigerant Charge
  43. Adjusting Sub-cooling and Superheat Temperatures
  44. Table 20 - R-410A Refrigerant Temperature-Pressure Chart
  45. Gas Heater Instructions
  46. Condenser Fan Electronically Commutated Motor (ECM) Startup
  47. VFD Controlled Condenser Fan Startup
  48. Adjustable Fan Cycling Switch Procedure
  49. Operation
  50. Packaged DX Cooling Operation and Control
  51. Maintenance
  52. Gas Heat Exchanger Removal
  53. Condensate Drain Pans
  54. Evaporator Coil (6-25 and 30 ton)
  55. Brazed Plate Heat Exchanger Cleaning
  56. Microchannel Coil Cleaning
  57. Supply Fans
  58. Phase and Brownout Protection Module
  59. Variable Capacity Compressor Controller
  60. Filter Replacement
  61. Filter Information
  62. Replacement Parts
  63. Appendix A - Heat Exchanger Corrosion Resistance
  64. Appendix B - Thermistor Temperature vs. Resistance Values
  65. rn series startup form
  66. maintenance log
  67. literature change history
  68. V76270 · Rev. A
RN Series first page preview

RN Series

Brand: AAON | Category: Fan
RN Series first page preview

RN Series

Brand: AAON | Category: Heat Pump
RN Series first page preview

RN Series

Brand: AAON | Category: Heating System
RN Series first page preview

RN Series

Brand: AAON | Category: Air Handlers
RN Series first page preview

RN Series

Brand: AAON | Category: Air Handlers