OneStart

Fujitsu Primergy BX920 S4 manuals

Primergy BX920 S4 first page preview

Primergy BX920 S4

Brand: Fujitsu | Category: Server
Table of contents
  1. server blade
  2. copyright and trademarks
  3. Table Of Contents
  4. Table Of Contents
  5. Table Of Contents
  6. Table Of Contents
  7. Table Of Contents
  8. Table Of Contents
  9. Table Of Contents
  10. Table Of Contents
  11. Table Of Contents
  12. version history
  13. Introduction
  14. Notational conventions
  15. Before you start
  16. Classification of procedures
  17. Upgrade and Repair Units (URU)
  18. Field Replaceable Units (FRU)
  19. Average task duration
  20. Tools you need at hand
  21. Documents you need at hand
  22. Important information
  23. CE conformity
  24. FCC Class A Compliance Statement
  25. Environmental protection
  26. Basic hardware procedures
  27. Locating the defective server blade
  28. Determining the error class
  29. Global Error indicator
  30. Customer Self Service (CSS) indicator
  31. Locating the defective component
  32. component leds
  33. Opening the rack door
  34. Shutting down the server blade
  35. Removing a server blade
  36. Removing the server blade from the system unit
  37. Opening the server blade
  38. Closing the server blade
  39. Installing the server blade in the system unit
  40. Switching on the server blade
  41. Concluding software tasks
  42. Closing the rack door
  43. Basic software procedures
  44. Checking the server blade status via iRMC
  45. Saving BIOS settings
  46. Disabling BitLocker functionality
  47. Disabling boot watchdog functionality
  48. Verifying and configuring the backup software solution
  49. Note on server maintenance in a Multipath I/O environment
  50. Switching on the ID indicator
  51. Completing the maintenance task
  52. Updating or recovering the iRMC
  53. Restoring BIOS settings
  54. Enabling Option ROM scan
  55. Resetting the boot retry counter
  56. Enabling boot watchdog functionality
  57. Enabling replaced components in the system BIOS
  58. Verifying the system time settings
  59. Viewing and clearing the System Event Log (SEL)
  60. Saving the SEL
  61. Clearing the SEL
  62. Enabling BitLocker functionality
  63. Performing a RAID array rebuild
  64. Looking up WWN addresses
  65. Using the Chassis ID Prom Tool
  66. After replacing the server blade
  67. Hard disk drives / solid state drives
  68. Basic information
  69. General equipping rules
  70. Installing a 2.5-inch HDD/SSD module
  71. Installing the 2.5-inch HDD/SSD module
  72. Concluding steps
  73. Removing a 2.5-inch HDD/SSD module
  74. Removing the 2.5-inch HDD/SSD module
  75. Installing the 2.5-inch dummy module
  76. Replacing a 2.5-inch HDD/SSD module
  77. Preliminary steps
  78. Replacing HDD/SSD backplanes
  79. Removing the HDD/SSD backplane
  80. Installing the HDD/SSD backplane
  81. Expansion cards and backup units
  82. Mezzanine cards
  83. Installing riser cards
  84. Removing riser cards
  85. Population rules for mezzanine cards
  86. expansion cards and backup units
  87. Installing mezzanine cards
  88. Installing a mezzanine card
  89. Removing mezzanine cards
  90. Removing a mezzanine card
  91. Replacing mezzanine cards
  92. SAS RAID HDD module
  93. Installing the SAS RAID HDD module
  94. Removing the SAS RAID HDD module
  95. Replacing the SAS RAID HDD module
  96. Installing the FBU (Flash Backup Unit)
  97. Installing the FBU
  98. Removing the FBU (Flash Backup Unit)
  99. Removing the FBU
  100. Replacing the FBU (Flash Backup Unit)
  101. Main memory
  102. Memory sequence
  103. Independant Channel mode
  104. Mirrored channel mode
  105. Performance channel mode
  106. Rank Sparing Mode for quad rank (4R) and octa rank (8R LRDIMM modules (minimizing waste of spare memory)
  107. Dummy DIMM modules
  108. Installing memory modules
  109. Installing a memory module
  110. Removing memory modules
  111. Removing a memory module
  112. Replacing memory modules
  113. Handling of memory air cowls
  114. Removing the air cowls
  115. Processors
  116. Installing processors
  117. Installing a processor
  118. Removing processors
  119. Removing a processor
  120. Upgrading or replacing processors
  121. Upgrading or replacing a processor
  122. Handling processor heat sinks
  123. Installing processor heat sinks
  124. Preparing the heat sink and processor
  125. Installing the heat sink
  126. Removing processor heat sinks
  127. Replacing processor heat sinks
  128. Applying thermal paste
  129. System board components
  130. Required tools
  131. Removing the battery
  132. Installing the CMOS battery
  133. USB Flash Module (UFM)
  134. Installing the UFM
  135. Software configuration
  136. Removing the UFM
  137. Replacing the UFM
  138. Re-installing the UFM
  139. Trusted Platform Module (TPM)
  140. Installing the TPM
  141. Removing the TPM
  142. Replacing the TPM
  143. Re-installing the TPM
  144. Onboard SAS enabling key
  145. Removing the defective onboard SAS enabling key
  146. Installing the new onboard SAS enabling key
  147. Replacing the system board
  148. Removing the system board
  149. Installing the system board
  150. Swapping the processor
  151. Server blade
  152. Replacing the server blade
  153. Appendix
  154. Server blade interior
  155. Configuration tables
  156. Connectors and indicators
  157. Onboard settings
  158. Onboard indicators and controls
  159. Connectors and indicators on the front
  160. Front panel indicators
  161. Indicators on the hot-plug HDD/SSD module
  162. Minimum startup configuration
Related products
PRIMERGY BX920 S1PRIMERGY BX924 S4PRIMERGY BX920 S2Primergy BX920 S3PRIMERGY BX620 S4PRIMERGY BX924 S3PRIMERGY BX924 S2PRIMERGY BX922 S2PRIMERGY BX900Primergy BX900 S2
Fujitsu categories
More Fujitsu categories