Magnetek Impulse 2007-VG+S4 manuals
Impulse 2007-VG+S4
Brand: Magnetek | Category: Controller
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- How to Use This Manual
- Introduction
- IMPULSE®•G+ & VG+ Series 4 General Specifications
- AC Reactor Specifications
- S4IF Interface Specifications
- IMPULSE®•G+ & VG+ Series 4 System Components And External Devices
- Long Time Storage
- Installing the Drive
- Multiple Drive Installation (Side-by-Side Installation)
- Drive Derating Data
- IMPULSE®•G+ & VG+ Series 4 Wiring Practices
- Suggested Circuit Protection Specifications and Wire Size
- Power Circuit Wiring Procedures
- Main Circuit Connection Diagram
- Terminal Block Configuration
- Insulation Barrier
- Interface Circuit Board
- Dip Switches
- Sinking/Sourcing Mode Selection for Safe Disable Inputs
- Control Circuit Terminals
- S4IF Control Circuit Terminal Diagrams
- Safe Torque Off
- Wiring the Encoder Circuit
- Encoder Wiring Diagrams and Information
- Overview
- Using the Keypad
- Keypad LED and Button Functions
- Parameter Modes
- Initialization Set-up
- X-Press Programming™
- Initialize Parameters (A01-05)
- User Parameters (A02-01 through 32)
- Auto-Tuning
- Standard Auto-Tune (T01-01 = 0) Instructions
- Non-Rotational Auto-Tune (T01-01 = 1) Instructions
- Terminal Resistance Auto-Tune (T01-01 = 2) Instructions
- Reference Limits
- Sequence/Reference Source
- Stop Method
- Coast to Stop (B03-03=1)
- Motor Rotation Change
- Acceleration/Deceleration
- Accel/Decel Time Switching Frequency
- Special Functions
- Quick Stop™
- Reverse Plug Simulation™
- Micro-Speed™
- End of Travel Limits
- Phantom Stop
- Klixon
- Hook Height Measurement
- Electronic Programmable Limit Switches (EPLS)
- Lower Limit/Upper Limit Bypass MFDI
- Load Float
- OLV and FLV Operation (A01-02 = 02 and 03)
- Swift-Lift™ & Ultra-Lift™
- Configuring the Swift-Lift & Ultra-Lift Function
- Torque Limit
- Anti-Shock
- No-Load Brake Hoist (VG+)
- E-Lift (VG+)
- Digital Input Option Set-up (DI-A3 and S4IO)
- Weight Measurement
- System Tare and Calibration for Weight Measurement
- Slack Cable Detection
- Snap Shaft Detection
- Brake Delay Timers
- Maintenance Timer
- Inching Control
- Index Function
- Tuning
- Motor Slip Compensation
- Automatic Speed Regulator (ASR) Tuning
- Torque Control
- Speed/Torque Control Switching
- S-Curve Acceleration/Deceleration
- Carrier Frequency
- Hunting Prevention
- Motor Parameters
- Motor Set-up
- Test Mode Configuration
- Option Card Parameters
- Analog Input (AI-A3) Option Set-up
- Analog Output (AO-A3) Option Set-up
- Digital Output (DO-A3) and S4IO Option Set-up
- Profibus-DP Communication Option Card Set-up
- Ethernet Option Card Set-up (Ethernet IP & Modbus TCP/IP)
- Terminal Parameters
- F1 and F2 Keys Function Selection
- Digital Outputs
- Digital Outputs—Alarm/Fault Annunciate (H02-01–03=40)
- Analog Inputs
- Analog Outputs
- Serial Communication Set-up
- Pulse Train Input/Output
- Protection Parameters
- Power Loss Ride Thru
- Stall Prevention
- Speed Agree
- Test Mode
- Torque Detection
- Hardware Protection
- Automatic Fault Reset
- Fault Latch Selection
- Operator Parameters
- Keypad Key Selection
- Maintenance History
- Copy Function
- Monitor Parameters
- Troubleshooting the Drive
- Troubleshooting Encoder Related Faults
- Fault Code: PGO-X-S/PGO-X-H–Pulse Generator Signal Fault
- Fault Code: BE1–Rollback Fault
- Fault Code: BE3–Brake Release Fault
- Alarm Code: BE6–Brake Proving Alarm
- Fault Code: OC–Over Current Fault
- Fault Display and Corrective Actions at Auto-Tuning
- Troubleshooting Option Card Related Faults
- Copy Function Related Faults
- Power Section Check
- S4IF Replacement Procedure