Mitsubishi Electric F700 manuals
F700
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- PRODUCT CHECKING AND PARTS IDENTIFICATION
- INSTALLATION AND WIRING
- Peripheral devices
- Method of removal and reinstallation of the front cover
- Installation of the inverter and instructions
- terminal connection diagram
- emc filter
- specification of main circuit terminal
- control circuit terminals
- changing the control logic
- wiring of control circuit
- when connecting the operation panel using a connection cable
- communication operation
- Connection of stand-alone option units
- connection of the brake unit (fr-bu/mt-bu)
- connection of the brake unit (bu type)
- connection of the power regeneration common converter (fr-cv)(55k or less)
- connection of the power regeneration converter (mt-rc) (75k or more)
- Power-off and magnetic contactor (MC)
- Precautions for use of the inverter
- the inverter
- Step of operation
- Operation panel (FR-DU07)
- basic operation (factory setting)
- operation lock (press [mode] for an extended time (2s)
- monitoring of output current and output voltage
- changing the parameter setting value
- overheat protection of the motor by the inverter (pr)
- when the rated motor frequency is 50hz (pr)
- Start/stop from the operation panel (PU operation mode)
- operation mode
- using the setting dial like a potentiometer at the operation
- setting the frequency by switches (three-speed setting)
- operation display
- start and stop using terminals (external operation)
- setting the frequency by switches (three-speed setting) (pr. 4 to pr)
- changing the output frequency (60hz, initial value) at the maximum voltage
- changing the output frequency (60hz, initial value) at the maximum current input
- Simple mode parameter list
- increasing the starting torque (pr)
- limiting the maximum and minimum output frequency (pr. 1, pr)
- changing acceleration and deceleration time (pr. 7, pr)
- energy saving operation (pr)
- Selection of the operation command and frequency command locations (Pr. 79)
- Parameter clear, all parameter clear
- Parameter copy and parameter verification
- parameter verification
- list of parameters classified by the purpose
- parameter list
- display of the extended parameters
- Reset method of protective function
- List of fault or alarm display
- Causes and corrective actions
- Correspondences between digital and actual characters
- Check and clear of the faults history
- check first when you have a trouble
- motor or machine is making abnormal acoustic noise
- motor rotates in the opposite direction
- speed varies during operation
- motor current is too large
- speed does not accelerate
- precautions for maintenance and inspection
- daily and periodic inspection
- display of the life of the inverter parts
- inspection item
- replacement of parts
- inverter replacement
- Rating
- Common specifications
- outline dimension drawings
- outline drawing
- Heatsink protrusion attachment procedure
- appendix 1 for customers who are replacing the conventional model
- instructions for installation
F700
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- OUTLINE
- WIRING
- Inverter and peripheral devices
- Peripheral devices
- Method of removal and reinstallation of the front cover
- front cover
- Installation of the inverter and enclosure design
- enclosure design
- Cooling system types for inverter enclosure
- EMC filter
- Main circuit terminal specifications
- Cables and wiring length
- When connecting the control circuit and the main circuit separately to the power supply
- Control circuit specifications
- Changing the control logic
- Control circuit terminal layout
- Wiring instructions
- When connecting the operation panel using a connection cable
- RS-485 terminal block
- Connection of stand-alone option units
- Connection of the brake unit (FR-BU/MT-BU5)
- Connection of the brake unit (BU type)
- Connection of the power regeneration common converter (FR-CV)(55K or less)
- Connection of the power regeneration converter (MT-RC) (75K or more)
- PRECAUTIONS FOR USE OF THE INVERTER
- EMC and leakage currents
- EMC measures
- Power supply harmonics
- Harmonic suppression guideline
- Installation of a reactor
- Inverter-driven 400V class motor
- Failsafe of the system which uses the inverter
- the inverter
- PARAMETERS
- Operation panel (FR-DU07)
- Basic operation (factory setting)
- Changing the parameter setting value
- Parameter list
- Adjustment of the output torque (current) of the motor
- Simple magnetic flux vector control (Pr.80, Pr.90)
- Slip compensation (Pr. 245 to Pr. 247)
- stall prevention operation
- Limiting the output frequency
- Avoiding mechanical resonance points (Frequency jump) (Pr. 31 to Pr. 36)
- V/F pattern
- Load pattern selection (Pr. 14)
- Adjustable 5 points V/F (Pr. 71, Pr. 100 to Pr. 109)
- Frequency setting by external terminals
- Jog operation (Pr. 15, Pr. 16)
- Input compensation of multi-speed and remote setting (Pr. 28)
- Remote setting function (Pr. 59)
- Setting of acceleration/deceleration time and acceleration/deceleration pattern
- Starting frequency and start-time hold function (Pr.13, Pr.571)
- Acceleration/deceleration pattern (Pr.29, Pr.140 to Pr.143)
- Selection and protection of a motor
- Applied motor (Pr. 71)
- Motor brake and stop operation
- Selection of a regenerative brake and DC feeding (Pr. 30, Pr. 70)
- Stop selection (Pr. 250)
- Output stop function (Pr.522)
- Function assignment of external terminal and control
- Inverter output shutoff signal (MRS signal, Pr. 17)
- Condition selection of function validity by the second function selection signal (RT) (RT signal Pr. 155)
- Start signal selection (STF, STR, STOP signal, Pr. 250)
- Output terminal function selection (Pr. 190 to Pr. 196)
- Detection of output frequency (SU, FU, FU2 signal, Pr. 41 to Pr. 43, Pr. 50)
- output current detection function
- Remote output function (REM signal, Pr. 495 to Pr. 497)
- Pulse train output of output power (Y79 signal, Pr. 799)
- Monitor display and monitor output signal
- du/pu monitor display selection
- FM, AM terminal function selection (Pr.55, Pr.56, Pr.867)
- Terminal FM, AM calibration Calibration parameter C0 (Pr. 900), C1 (Pr. 901))
- Operation selection at power failure and instantaneous power failure
- instantaneous power failure
- Power failure-time deceleration-to-stop function (Pr. 261 to Pr. 266 )
- operation selection at power failure
- Operation setting at fault occurrence
- Fault code output selection (Pr.76)
- Input/output phase loss protection selection (Pr. 251, Pr. 872)
- Energy saving operation and energy saving monitor
- Energy saving monitor (Pr. 891 to Pr. 899)
- Motor noise, EMI measures, mechanical resonance
- Speed smoothing control (Pr. 653, Pr. 654)
- Frequency setting by analog input (terminal 1, 2, 4)
- Analog input compensation (Pr. 73, Pr. 242, Pr. 243, Pr. 252, Pr. 253)
- Response level of analog input and noise elimination (Pr. 74)
- Bias and gain of frequency setting voltage (current Pr. 125, Pr. 126, Pr. 241, C2(Pr. 902) to C7(Pr. 905))
- operation display
- Misoperation prevention and parameter setting restriction
- Parameter write selection (Pr. 77)
- Reverse rotation prevention selection (Pr. 78)
- Selection of operation mode and operation location
- Operation mode at power on (Pr. 79, Pr. 340)
- Start command source and speed command source during communication operation (Pr. 338, Pr. 339, Pr. 550, Pr. 551)
- Communication operation and setting
- system configuration
- Wiring and arrangement of RS-485 terminals
- initial settings and specifications of rs-485 communication
- Communication EEPROM write selection (Pr. 342)
- Mitsubishi inverter protocol (computer link communication)
- run command
- modbus-rtu communication specifications
- Special operation and frequency control
- special operation and frequency control
- Bypass-inverter switchover function (Pr. 135 to Pr. 139, Pr. 159)
- Regeneration avoidance function (Pr. 882 to Pr. 886)
- Useful functions
- Display of the life of the inverter parts (Pr. 255 to Pr .259)
- Maintenance timer alarm (Pr. 503, Pr. 504)
- Current average value monitor signal (Pr. 555 to Pr. 557)
- Free parameter (Pr. 888, Pr. 889)
- Setting from the parameter unit, operation panel
- Buzzer control (Pr. 990)
- Parameter clear
- All parameter clear
- Parameter copy and parameter verification
- Parameter verification
- Check and clear of the faults history
- Reset method of protective function
- List of fault or alarm display
- Causes and corrective actions
- Correspondences between digital and actual characters
- Check first when you have a trouble
- Motor or machine is making abnormal acoustic noise
- Motor rotates in the opposite direction
- Speed varies during operation
- Operation panel (FR-DU07) display is not operating
- Speed does not accelerate
- PRECAUTIONS FOR
- Inspection item
- Daily and periodic inspection
- Display of the life of the inverter parts
- Cleaning
- Inverter replacement
- Measurement of main circuit voltages, currents and powers
- Measurement of powers
- Measurement of currents
- SPECIFICATIONS
- Rating
- Common specifications
- Outline dimension drawings
- Heatsink protrusion attachment procedure
- Appendix 1 For customers who are replacing the conventional model with this inverter
- instructions for installation
- Appendix 2 Parameter clear, parameter copy and instruction code list
- Appendix 3 Specification change
- changed functions
F700
Table of contents
- instruction manual
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- OUTLINE
- WIRING
- Inverter and peripheral devices
- Peripheral devices
- Method of removal and reinstallation of the front cover
- SPECIFICATIONS
- enclosure design
- Cooling system types for inverter enclosure
- EMC filter
- Main circuit terminal specifications
- Cables and wiring length
- When connecting the control circuit and the main circuit separately to the power supply
- Control circuit specifications
- Changing the control logic
- Control circuit terminal layout
- Wiring instructions
- When connecting the operation panel using a connection cable
- RS-485 terminal block
- Connection of stand-alone option units
- Connection of the brake unit (FR-BU/MT-BU5)
- Connection of the brake unit (BU type)
- Connection of the power regeneration common converter (FR-CV)(01160 or less)
- Connection of the power regeneration converter (MT-RC) (01800 or more)
- PRECAUTIONS FOR USE OF THE INVERTER
- EMC and leakage currents
- EMC measures
- Power supply harmonics
- Installation of a reactor
- Inverter-driven 400V class motor
- Failsafe of the system which uses the inverter
- PARAMETERS
- Operation panel (FR-DU07)
- Basic operation (factory setting)
- Changing the parameter setting value
- Parameter list
- Adjustment of the output torque (current) of the motor
- Simple magnetic flux vector control (Pr.80, Pr.90)
- Slip compensation (Pr. 245 to Pr. 247)
- stall prevention operation
- Multiple rating (Pr.570)
- Limiting the output frequency
- Avoiding mechanical resonance points (Frequency jump) (Pr. 31 to Pr. 36)
- V/F pattern
- Load pattern selection (Pr. 14)
- Adjustable 5 points V/F (Pr. 71, Pr. 100 to Pr. 109)
- Frequency setting by external terminals
- Jog operation (Pr. 15, Pr. 16)
- Input compensation of multi-speed and remote setting (Pr. 28)
- Remote setting function (Pr. 59)
- Setting of acceleration/deceleration time and acceleration/deceleration pattern
- Starting frequency and start-time hold function (Pr.13, Pr.571)
- Acceleration/deceleration pattern (Pr.29, Pr.140 to Pr.143)
- Selection and protection of a motor
- Applied motor (Pr. 71)
- Motor brake and stop operation
- Selection of a regenerative brake and DC feeding (Pr. 30, Pr. 70)
- Stop selection (Pr. 250)
- Output stop function (Pr.522)
- Function assignment of external terminal and control
- Inverter output shutoff signal (MRS signal, Pr. 17)
- Condition selection of function validity by the second function selection signal (RT) (RT signal Pr. 155)
- Start signal selection (STF, STR, STOP signal, Pr. 250)
- Output terminal function selection (Pr. 190 to Pr. 196)
- Detection of output frequency (SU, FU, FU2 signal, Pr. 41 to Pr. 43, Pr. 50)
- output current detection function
- Remote output function (REM signal, Pr. 495 to Pr. 497)
- Pulse train output of output power (Y79 signal, Pr. 799)
- Monitor display and monitor output signal
- du/pu monitor display selection
- CA, AM terminal function selection (Pr.55, Pr.56, Pr.867, Pr.869)
- Terminal CA, AM calibration Calibration parameter C0 (Pr. 900), C1 (Pr. 901), C8 (Pr.930) to C11 (Pr. 931))
- Operation selection at power failure and instantaneous power failure
- instantaneous power failure
- Power failure-time deceleration-to-stop function (Pr. 261 to Pr. 266 )
- operation selection at power failure
- Operation setting at fault occurrence
- Fault code output selection (Pr.76)
- Input/output phase loss protection selection (Pr. 251, Pr. 872)
- Energy saving operation and energy saving monitor
- Energy saving monitor (Pr. 891 to Pr. 899)
- Motor noise, EMI measures, mechanical resonance
- Speed smoothing control (Pr. 653, Pr. 654)
- Frequency setting by analog input (terminal 1, 2, 4)
- Analog input compensation (Pr. 73, Pr. 242, Pr. 243, Pr. 252, Pr. 253)
- Response level of analog input and noise elimination (Pr. 74)
- Bias and gain of frequency setting voltage (current Pr. 125, Pr. 126, Pr. 241, C2(Pr. 902) to C7(Pr. 905))
- operation display
- mA input check of current input (Pr. 573)
- Misoperation prevention and parameter setting restriction
- Parameter write selection (Pr. 77)
- Reverse rotation prevention selection (Pr. 78)
- Selection of operation mode and operation location
- Operation mode at power on (Pr. 79, Pr. 340)
- Start command source and speed command source during communication operation (Pr. 338, Pr. 339, Pr. 550, Pr. 551)
- Communication operation and setting
- system configuration
- Wiring and arrangement of RS-485 terminals
- initial settings and specifications of rs-485 communication
- Communication EEPROM write selection (Pr. 342)
- Mitsubishi inverter protocol (computer link communication)
- run command
- modbus-rtu communication specifications
- Special operation and frequency control
- special operation and frequency control
- Bypass-inverter switchover function (Pr. 135 to Pr. 139, Pr. 159)
- Advanced PID function (pump function) (Pr. 554, Pr. 575 to Pr. 591)
- Traverse function (Pr. 592 to Pr. 597)
- Regeneration avoidance function (Pr. 882 to Pr. 886)
- Useful functions
- Display of the life of the inverter parts (Pr. 255 to Pr .259)
- Maintenance timer alarm (Pr. 503, Pr. 504)
- Current average value monitor signal (Pr. 555 to Pr. 557)
- Free parameter (Pr. 888, Pr. 889)
- Setting from the parameter unit, operation panel
- Buzzer control (Pr. 990)
- Parameter clear
- All parameter clear
- Parameter copy and parameter verification
- Parameter verification
- Check and clear of the faults history
- Reset method of protective function
- List of fault or alarm display
- Causes and corrective actions
- Correspondences between digital and actual characters
- Check first when you have a trouble
- Motor or machine is making abnormal acoustic noise
- Motor rotates in the opposite direction
- Speed varies during operation
- Operation panel (FR-DU07) display is not operating
- Speed does not accelerate
- PRECAUTIONS FOR
- Inspection item
- Daily and periodic inspection
- Display of the life of the inverter parts
- Cleaning
- Inverter replacement
- Measurement of main circuit voltages, currents and powers
- Measurement of powers
- Measurement of currents
- Measurement of converter output voltage (across terminals P/+ - N/-)
- Rating
- Common specifications
- Outline dimension drawings
- Heatsink protrusion attachment procedure
- Appendix 1 For customers who are replacing the conventional model with this inverter
- instructions for installation
- Appendix 2 Parameter clear, parameter copy and instruction code list
- Appendix 3 Specification change
F700
Table of contents
- PRODUCT CHECKING AND PARTS IDENTIFICATION
- INSTALLATION AND WIRING
- Peripheral devices
- Method of removal and reinstallation of the front cover
- front cover
- Installation of the inverter and instructions
- Wiring
- emc filter
- specification of main circuit terminal
- control circuit terminals
- changing the control logic
- wiring of control circuit
- when connecting the operation panel using a connection cable
- communication operation
- Power-off and magnetic contactor (MC) 24
- Precautions for use of the inverter
- DRIVE THE MOTOR
- Operation panel (FR-DU07)
- monitoring of output current and output voltage
- change the parameter setting value
- Start/stop from the operation panel (PU operation mode)
- operation mode
- Make a start and stop with terminals (external operation)
- external operation
- ADJUSTMENT
- Selection of the operation command and frequency command locations (Pr. 79)
- Parameter copy and parameter verification
- parameter verification
- Parameter list
- Extended parameters
- Reset method of protective function
- List of alarm display
- Causes and corrective actions
- Correspondences between digital and actual characters
- Check and clear of the alarm history
- Check first when you have troubles
- motor rotates in opposite direction
- Inspection item
- daily and periodic inspection
- display of the life of the inverter parts
- replacement of parts
- inverter replacement
- SPECIFICATIONS
- Outline dimension drawings
- Heatsink protrusion attachment procedure
- instructions for installation
F700
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- OUTLINE
- WIRING
- Inverter and peripheral devices
- peripheral devices
- method of removal and reinstallation of the front cover
- front cover
- enclosure design
- cooling system types for inverter enclosure
- terminal connection diagram
- emc filter
- Main circuit terminal specifications
- cables and wiring length
- PROTECTIVE FUNCTIONS
- when connecting the control circuit and the main circuit separately
- Control circuit specifications
- specifications
- changing the control logic
- control circuit terminal layout
- when connecting the operation panel using a connection cable
- communication operation
- Connection of stand-alone option units
- Connection of the brake unit (BU type)
- Connection of the power regeneration common converter (FR-CV)(55K or less)
- Connection of power regeneration converter (MT-RC) (75K or more)
- PRECAUTIONS FOR USE OF THE INVERTER
- Noise and leakage currents
- Inverter-generated noises and their reduction techniques
- power supply harmonics
- harmonic suppression guideline
- Installation of a reactor
- Inverter-driven 400V class motor
- PARAMETERS
- Operation panel (FR-DU07)
- Basic operation (factory setting)
- change the parameter setting value
- Parameter List
- Adjust the output torque of the motor (current)
- Simple magnetic flux vector control (Pr.80, Pr.90)
- Slip compensation (Pr. 245 to Pr. 247)
- stall prevention operation
- Limit the output frequency
- Avoid mechanical resonance points (Frequency jump) (Pr. 31 to Pr. 36)
- Set V/F pattern
- Load pattern selection (Pr. 14)
- Adjustable 5 points V/F (Pr. 71, Pr. 100 to Pr. 109)
- Frequency setting by external terminals
- Jog operation (Pr. 15, Pr. 16)
- Input compensation of multi-speed and remote setting (Pr. 28)
- Remote setting function (Pr. 59)
- acceleration/deceleration pattern
- Starting frequency and start-time hold function (Pr.13, Pr.571)
- Acceleration/deceleration pattern (Pr.29, Pr.140 to Pr.143)
- Selection and protection of a motor
- Applied motor (Pr. 71)
- Motor brake and stop operation
- Selection of a regenerative brake (Pr. 30, Pr. 70)
- Stop selection (Pr. 250)
- function assignment of external terminal and control
- Inverter output shutoff signal (MRS signal, Pr. 17)
- Condition selection of function validity by the second function selection signal (RT) (RT signal Pr. 155)
- Start signal selection (STF, STR, STOP signal, Pr. 250)
- Output terminal function selection (Pr. 190 to Pr. 196)
- Detection of output frequency (SU, FU, FU2 signal, Pr. 41 to Pr. 43, Pr. 50)
- output current detection function
- Remote output function (REM signal, Pr. 495 to Pr. 497)
- Monitor display and monitor output signal
- FM, AM terminal function selection (Pr.55, Pr.56, Pr.867)
- Terminal FM, AM calibration Calibration parameter C0 (Pr. 900), C1 (Pr. 901))
- Operation selection at power failure and instantaneous power failure
- operation selection at power failure
- Operation setting at alarm occurrence
- Alarm code output selection (Pr.76)
- Input/output phase failure protection selection (Pr. 251, Pr. 872)
- energy saving operation and energy saving monitor
- Energy saving monitor (Pr. 891 to Pr. 899)
- Motor noise, noise reduction
- Frequency setting by analog input (terminal 1, 2, 4)
- Analog input compensation (Pr. 73, Pr. 242, Pr. 243, Pr. 252, Pr. 253)
- Response level of analog input and noise elimination (Pr. 74)
- Bias and gain of frequency setting voltage (current Pr. 125, Pr. 126, Pr. 241, C2(Pr. 902) to C7(Pr. 905))
- misoperation prevention and parameter setting restriction
- Parameter write selection (Pr. 77)
- Reverse rotation prevention selection (Pr. 78)
- selection of operation mode and operation location
- Operation mode at power on (Pr. 79, Pr. 340)
- operation command source and speed command source during
- Communication operation and setting
- system configuration
- Wiring and arrangement of RS-485 terminals
- Communication EEPROM write selection (Pr. 342)
- Mitsubishi inverter protocol (computer link communication)
- Special operation and frequency control
- Bypass-inverter switchover function (Pr. 135 to Pr. 139, Pr. 159)
- Regeneration avoidance function (Pr. 882 to Pr. 886)
- Useful functions
- Display of the life of the inverter parts (Pr. 255 to Pr .259)
- Maintenance timer alarm (Pr. 503, Pr. 504)
- Current average value monitor signal (Pr. 555 to Pr. 557)
- Free parameter (Pr. 888, Pr. 889)
- Setting from the parameter unit, operation panel
- Buzzer control (Pr. 990)
- Parameter clear
- All parameter clear
- Parameter copy and parameter verification
- parameter verification
- Check and clear of the alarm history
- Reset method of protective function
- List of alarm display
- Causes and corrective actions
- correspondences between digital and actual characters
- check first when you have troubles
- motor rotates in opposite direction
- operation mode is not changed properly
- precautions for
- precautions for maintenance and inspection
- daily and periodic inspection
- display of the life of the inverter parts
- replacement of parts
- inverter replacement
- measurement of voltages and currents
- measurement of powers
- measurement of currents
- insulation resistance test using megger
- Rating
- Common specifications
- outline dimension drawings
- heatsink protrusion attachment procedure
- APPENDICES
- Appendix 1 For customers who have replaced the older model with this inverter
- instructions for installation
- Appendix 2 Control mode-based parameter (function) correspondence table and instruction code list
F700
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- WIRING
- Inverter and peripheral devices
- Peripheral devices
- SPECIFICATIONS
- Cables and wiring length
- PROTECTIVE FUNCTIONS
- Control circuit terminal layout
- Wiring instructions
- When connecting the control circuit and the main circuit separately to the power supply (separate power)
- Changing the control logic
- Connection of stand-alone option units
- Connection of the brake unit (BU type)
- Connection of the power regeneration common converter (FR-CV)
- When connecting the operation panel using a connection cable
- PRECAUTIONS FOR USE OF THE INVERTER
- Panel design
- Cooling system types for inverter panel
- Inverter placement
- Others
- Power-off and magnetic contactor (MC)
- Inverter-generated noises and their reduction techniques
- EMC filter
- Power supply harmonics
- Inverter-driven 400V class motor
- PARAMETERS
- Parameter List
- Adjust the output torque of the motor (current)
- Simple magnetic flux vector control (Pr.80, Pr.90)
- Slip compensation (Pr. 245 to Pr. 247)
- Load pattern selection (Pr.14)
- Multiple rating (Pr.570)
- Limit the output frequency
- Avoid mechanical resonance points (Frequency jump) (Pr. 31 to Pr. 36)
- Set V/F pattern
- Adjustable 5 points V/F (Pr. 71, Pr. 100 to 109)
- Frequency setting by external terminals
- Jog operation (Pr. 15, Pr. 16)
- Input compensation of multi-speed and remote setting (Pr. 28)
- Remote setting function (Pr. 59)
- Setting of acceleration/deceleration time and acceleration/deceleration pattern
- Starting frequency and start-time hold function (Pr.13, Pr.571)
- Acceleration/deceleration pattern (Pr.29, Pr.140 to Pr.143)
- Selection and protection of a motor
- Applied motor (Pr.71)
- Motor brake and stop operation
- Selection of a regenerative brake (Pr. 30, Pr.70)
- Stop selection (Pr.250)
- Function assignment of external terminal and control
- Inverter output shutoff signal (MRS signal, Pr. 17)
- Second function RT signal reflection time selection (Terminal RT, Pr. 155)
- Start signal selection (Terminal STF, STR, STOP, Pr. 250)
- Output terminal function selection (Pr. 190 to Pr. 196)
- Detection of output frequency (SU, FU, FU2 signal, Pr. 41 to Pr. 43, Pr. 50)
- Remote output function (REM signal, Pr. 495 to Pr. 497)
- Monitor display and monitor output signal
- DU/PU monitor display selection (Pr.52, Pr.170, Pr.171, Pr.268, Pr.563, Pr.564, Pr.891)
- CA, AM terminal function selection (Pr.54 to Pr.56, Pr.158, Pr.867, Pr.869)
- Terminal CA, AM calibration (Calibration parameter C0 (Pr. 900), C1 (Pr. 901), C8 (pr.930) to C11 (Pr. 931))
- Operation selection at power failure and instantaneous power failure
- Power failure-time deceleration-to-stop function (Pr. 261 to Pr. 266)
- Operation setting at alarm occurrence
- Alarm code output selection (Pr.76)
- Input/output phase failure protection selection (Pr.251, Pr.872)
- Energy saving operation and energy saving monitor
- Energy saving monitor (Pr. 891 to Pr. 899)
- Motor noise, noise reduction
- Frequency setting by analog input (terminal 1, 2, 4)
- Analog input compensation (Pr.73, Pr.242, Pr.243, Pr.252, Pr.253)
- Input filter time constant (Pr.74)
- Bias and gain of frequency setting voltage (current Pr. 125, Pr. 126, Pr. 241, C2(Pr. 902) to C7(Pr. 905))
- mA input check of current input (Pr. 573)
- Misoperation prevention and parameter setting restriction
- Parameter write disable selection (Pr.77)
- Reverse rotation prevention selection (Pr.78)
- Selection of operation mode and operation location
- Operation mode at power on (Pr. 79, Pr. 340)
- Operation command source and speed command source during communication operation (Pr. 338, Pr. 339, Pr. 550, Pr. 551)
- Communication operation and setting
- Wiring and arrangement of RS-485 terminals
- Communication EEPROM write selection (Pr. 342)
- Mitsubishi inverter protocol (computer link communication)
- Modbus-RTU communication specifications (Pr. 331, Pr. 332, Pr. 334, Pr. 343, Pr. 549)
- Special operation and frequency setting
- Commercial power supply-inverter switchover function (Pr. 135 to Pr. 139, Pr. 159)
- Advanced PID function (pump function) (Pr. 575 to Pr. 591)
- Traverse function (Pr. 592 to Pr. 597)
- Regeneration avoidance function (Pr.882 to Pr.886)
- Useful functions
- Display of the life of the inverter parts (Pr. 255 to Pr .259)
- Maintenance timer alarm (Pr.503, Pr.504)
- Current average value monitor signal (Pr.555 to Pr.557)
- Free parameter (Pr.888, Pr.889)
- Setting from the parameter unit, operation panel
- Buzzer control (Pr. 990)
- Parameter clear
- All parameter clear
- Parameter copy
- Parameter verification
- Check and clear of the alarm history
- List of alarm display
- Causes and corrective actions
- Reset method of protective function
- Meters and measuring methods
- Measurement of voltages and use of PT
- Use of CT and transducer
- Check first when you have troubles
- Motor rotates in opposite direction
- Rating
- Common specifications
- Outline dimension drawings
- Operation panel (FR-DU07) outline dimension drawings