red lion ITMA DC Quick Start Manual
1! USER PROGRAMMABLE INPUT(Thermocouple types J, K, T, & E, or millivolt)! MICROPROCESSOR CONTROLLED! SIMPLE ADJUSTABLE RANGE SETTING (Using Input Signal)! THERMOCOUPLE BREAK DETECTION! MOUNTS ON “T” AND “G” STYLE DIN RAILS! 3-WAY ELECTRICAL ISOLATION (POWER/INPUT/OUTPUT)! MULTIPLE ANALOG OUTPUTS (0 to 20 mA, 4 to 20 mA, and 0 to10 VDC)! WIDE OPERATING TEMPERATURE RANGE (-25°C to 75°C)! POWER & MEMORY ERROR INDICATION! 9 to 32 VDC POWEREDDESCRIPTIONThe ITMA accepts a thermocouple or millivolt input and converts it into avoltage or current output. The voltage or current output is linearly proportionalto the temperature or millivolt input. This output is ideal for interfacing toindicators, chart recorders, controllers, or other instrumentation equipment.The ITMA is DC powered. The DC power input is isolated from the signalinput and analog output. The unit scales the analog output proportionally to thethermocouple or millivolt input signal. The analog output may be configured forone of the following: 0 to 20 mA, 4 to 20 mA, or 0 to 10 VDC. Making thesignal conversion with the ITMA to a current output signal, makes the signalless susceptible to noise interference and allows accurate transmission over longdistances. The 3-Way isolation allows the use of grounded thermocouples whichcan provide additional noise reduction benefits.The ITMA uses a ten position DIP switch to accomplish the input sensorconfiguration, range selection, and unit calibration. A simple range settingtechnique (Field Calibration) is used so the actual input signal adjusts the outputfor scaling. This technique eliminates the need for potentiometers which arevulnerable to changes due to vibration.The unit is equipped with a universal mounting foot for attachment tostandard DIN style mounting rails, including top hat rail (T) according to EN 50022 - 35 × 7.5 and 35 × 15, and (G) profile according to EN 50 035 - G 32.SAFETY SUMMARYAll safety related regulations, local codes and instructions that appear in themanual or on equipment must be observed to ensure personal safety and toprevent damage to either the instrument or equipment connected to it. Ifequipment is used in a manner not specified by the manufacturer, the protectionprovided by the equipment may be impaired.SPECIFICATIONS1. POWER: 9 to 32 VDC; 1.75 W The power supply must have 300 mA for200 msec. surge capacity.2. INPUT: J, K, T, E, mV [selectable via DIP switch]3. OUTPUT: All output signals scaled linearly using temperature or mV input.Unit is shipped set for 4 to 20 mA output. 4 to 20 mA or 0 to 20 mA selectedvia internal jumper.Voltage Output Compliance:0 to 10 VDC across min 1 KΩ load (10 mA)20 mV peak to peak max. ripple (for frequencies up to 120 Hz)Current Output Compliance:0 to 20 mA through max. 600Ω load (12 VDC)4 to 20 mA through max. 600Ω load (12 VDC)15 mV peak to peak max. ripple across 600Ω load (for freq. up to 120 Hz)4. TC BREAK DETECTION: Nominal values shown in the following order:(0 to 20 mA, 4 to 20 mA, and 0 to 10 VDC).Upscale: 22.9 mA, 22.5 mA, and 11.5 VDCDownscale: -0.5 mA, 3.5 mA, and -0.4 VDC5. RESPONSE TIME: 400 msec (to within 99% of final value w/step input;typically, response is limited to response time of probe.)6. TEMPERATURE EFFECTS:Temperature Coefficient: ± 0.025% of input range per °CIce Point Compensation: ± 0.75°C for a 50°C change in temperature7. DIELECTRIC WITHSTAND VOLTAGE: 1500 VAC for 1 minuteWorking Voltage: 50 VACPower input to Signal input, Power input to Signal output, & Signal input toSignal output.8. RANGE & ACCURACY: (12 Bit resolution)Accuracy: ± ( 0.075% Range + 0.25°C [Conformity] + 0.50°C [Ice Point])at 23°C after 20 min. warm-up, conforming to ITS-90.Note: TC Conformity and Ice Point do not apply to mV inputMODEL ITMA DC - INTELLIGENT THERMOCOUPLE MODULE WITH ANALOG OUTPUTDIMENSIONS In inches (mm)CAUTION: Read complete instructions priorto installation and operation of the unit.Bulletin No. ITMA3-BDrawing No. LP0405Released 6/03Tel +1 (717) 767-6511Fax +1 (717) 764-6587www.redlion-controls.com |
Related manuals for red lion ITMA DC
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved