red lion CUB4LP User Manual
Contents |
ORDERING INFORMATIONMODEL NO. DESCRIPTION PART NUMBERSCUB4LPReflective LCD Loop Powered Process Indicator CUB4LP00Red Backlit LCD Loop Powered Process IndicatorPositive Image Transflective LCD *CUB4LP40CUB4CLYel/Grn Backlit LCD External Powered ProcessIndicator Negative Image Transmissive LCD CUB4CL10Red Backlit LCD External Powered ProcessIndicator Negative Image Transmissive LCD CUB4CL20Yel/Grn Backlit LCD External Powered ProcessIndicator Positive Image Transflective LCD CUB4CL30Red Backlit LCD External Powered ProcessIndicator Positive Image Transflective LCD CUB4CL40MLPS Micro Line/Sensor Power Supply(Non-hazardous use only) MLPS1000*Backlight intensity will vary depending on signal level.CALIBRATING THE DISPLAYCalibrating the CUB4LP/CL requires either an accurate adjustable constantcurrent supply or the CUB4LP/CL can be installed and scaled with the processsensor connected to the CUB4LP/CL. To calibrate the unit, proceed as follows.1. Set DIP switching for the desired current range.2. Select the desired decimal point position.3. Apply the minimum input signal to the CUB4LP/CL and adjust the COARSEOFFSET to display the approximate desired minimum value.4. Apply the maximum input signal to the CUB4LP/CL and adjust the COARSESPAN to display the approximate desired maximum value.5. Repeat steps 3 and 4 until the minimum and maximum values are within thedesired values.6. Apply the minimum input signal to the CUB4LP/CL and adjust the FINEOFFSET to display the exact desired minimum value.7. Apply the maximum input signal to the CUB4LP/CL and adjust the FINESPAN to display the exact desired maximum value.8. Apply the minimum input signal and verify that the display indicatescorrectly.9. Apply the maximum input signal and verify that the display indicatescorrectly.10. Repeat Steps 6 through 9 until display reads exact.Note: The CUB4LP/CL display is factory calibrated to indicate 0.0 to 100.0with an input of 4 to 20 mA at approximately 25°C.BLOCK DIAGRAMPROCESSCIRCUITRYS4 S3 S2SIG-SIG++VDCCOMS18.25Ω12.7Ω COARSESPANGND1234BACKLIGHTFINEOFFSETOFFSETCOARSEFINESPAN-V+V0.1 μf50 VDC(CL ONLY)(CL ONLY)Connection forCUB4LP40DECIMAL POINT POSITION SELECTIONThe decimal point position is DIP switch selectable for one of three locations.The CUB4LP/CL can be set up to read in 10ths, 100ths, or 1000ths. If all theDIP switches are set to the “OFF” position, no decimal point will appear on thedisplay. The DIP switches are located at the rear of the unit.APPLICATION EXAMPLEOperation of a refinery process required a local display of the position of aremote pipeline valve. The display would indicate 0 (zero) when the valve wasfully closed with an input signal of 4 mA. When the valve was fully open thedisplay would indicate 100 with an input signal of 20 mA.Both the CUB4LP and the CUB4CL meet the necessary requirements.VALVECONTROLDEVICE+ +--CUB4LPSIG +COMM(SIG -)TROUBLESHOOTINGFor further technical assistance, contact technicalsupport at the appropriate company numbers listed.Red Lion ControlsHeadquarters20 Willow Springs CircleYork PA 17406Tel +1 (717) 767-6511Fax +1 (717) 764-0839Red Lion ControlsChinaUnit 302, XinAn PlazaBuilding 13, No.99 Tianzhou RoadShangHai, P.R. China 200223Tel +86 21 6113 3688Fax +86 21 6113 3683Red Lion ControlsEuropeSoftwareweg 9NL - 3821 BN AmersfoortTel +31 (0) 334 723 225Fax +31 (0) 334 893 793Red Lion ControlsIndia201-B, 2nd Floor, Park CentraOpp 32 Mile Stone, Sector-30Gurgaon-122002 Haryana, IndiaTel +91 984 487 0503 |
Related manuals for red lion CUB4CL
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved