red lion APOLLO Manual
Also see for APLIT: Manual
1l3 1/2-DIGIT, 0.56” (14.2 mm) HIGH LED DISPLAYlSELECTABLE DECIMAL POINT LOCATIONlBUILT-IN SCALING PROVISIONSlAUTO ZEROING CIRCUITSlOVER-RANGE INDICATIONlNEMA 4/IP65 SEALED FRONT METAL BEZELDESCRIPTIONThe Model APLIT Apollo 5 amp AC Current Meter provides the capabilityof measuring large AC currents. The internal current shunt in the APLIT canmeasure up to 5 amps AC current directly. Using an external currenttransformer, AC currents of up to 1,999 amps can be measured and displayed.The APLIT can be scaled, using the coarse scaling pot., to display between200 and 1999 when measuring full scale current. Using the DIP switchselectable decimal points, the display can be customized for direct readout forpractically any application.The attractive die-cast metal bezel of the Apollo not only enhances theappearances of any panel, it can be sealed in the front panel for use in wash-down areas and tough, dirty industrial environments. The 3 1/2-digit displayfeatures 0.56” (14.2 mm) high, 7-segment LED’s for easy reading. Alsofeatured is a removable terminal block on the rear that facilitates installationwiring and change-outs.SAFETY SUMMARYAll safety related regulations, local codes and instructions that appear in themanual or on equipment must be observed to ensure personal safety and toprevent damage to either the instrument or equipment connected to it. Ifequipment is used in a manner not specified by the manufacturer, the protectionprovided by the equipment may be impaired.SPECIFICATIONS1. DISPLAY: 3 1/2-digit, 0.56” (14.2 mm) high, 7-segment LED. Decimalpoints inserted before the 1st, 2nd, or 3rd least significant digits by DIPswitch selection.2. POWER: Available in either 115 VAC or 230 VAC versions. Allowablepower line variation ±10%, 50/60 Hz, 6 VA.Isolation: 2300 Vrms for 1 min. between inputs and supply (300 V workingvoltage).3. ACCURACY: ±(0.5% of reading + 5 digits).4. SIGNAL INPUT:Range: 0 to 5 Amps AC @ 25 to 400 HzResolution: 2.5 mA5. OVER-RANGE INDICATION: indicated by blanking 3 least significantdigits.6. MAX SHUNT CURRENT: 50 amps for 1 sec.; 8 amps continuous.Caution: In circuits where fault currents can exceed the maximum shuntcurrent, a fast-blow fuse should be installed in series with the input signal.Otherwise, a slow blow 8 amp fuse is recommended that will allow forstart-up over current situations, while still protecting the instrument.7. ENVIRONMENTAL CONDITIONS:Operating Temperature : 0o to 60oCStorage Temperature : -40 o to 80oCTemperature Coefficient: ±200 PPM/oCOperating and Storage Humidity: 85% max. relative humidity (non-condensing) from 0°C to 50°C.Altitude: Up to 2000 meters8. RESPONSE TIME TO STEP CHANGE INPUT: 1 sec. nominal9. READING RATE: 2.5 readings/sec., nominal10. CONSTRUCTION: Metal die-cast front bezel with black, high impactplastic insert case. This unit is rated for NEMA 4/IP65 indoor use whenproperly installed (panel gasket and mounting clips included). InstallationCategory II, Pollution Degree 2.MODEL APLIT - APOLLO 5 AMP AC CURRENT METERDIMENSIONS “In inches (mm)” Note: Recommended minimum clearance (behind the panel) formounting clip installation is 2.1” (53.4) H x 5.5” (140) W. PANEL CUT-OUTORDERING INFORMATIONMODEL NUMBER DESCRIPTION PART NUMBERSApollo 5 amp AC Current Meter230 VAC 115 VACAPLIT APLIT415For more information on Pricing, Enclosures, & Panel Mount Kits refer to theRLC Catalog or contact your local RLC distributor.APLIT405INTERNATIONAL HEADQUARTERSEUROPEAN HEADQUARTERS20 Willow Springs Circle, York, Pa. 17402, (717) 767-6511 FAX: (717) 764-0839 892 Plymouth Road, Slough, Berkshire SL1 4LPWeb site- http://www.redlion-controls.com E-mail- sales@redlion-controls.com ENGLAND +44 1753 696888 FAX: +44 1753 696339RED LION CONTROLSBULLETIN NO. APLIT-FDRAWING NO. LP0149REVISED 3/99CAUTION: Read completeinstructions prior to installationand operation of the unit.CAUTION: Risk of electric shock. |
Related manuals for red lion APLIT
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved