Ziton ZP755BV-4P Installation Sheet
2 / 4 P/N 10-5202-501-ZV01-12 • ISS 05OCT21Setting the addressThe sounder includes a seven-segment DIP switch (SW1) forassigning device addresses. Each switch segment has adecimal value as shown in Figure 3. The address is the sum ofall the switch segments in the ON position. The switch is usedto set the device address in binary code. The switch may beset to represent any address from 1 to 127.For example, to select a device address of 007, set SW1-1,SW1-2, and SW1-3 to the ON position and the remainingswitch segments to the OFF position.Figure 3: Address switch settingMode, tone, and volume settingsThe sounder includes a seven-segment DIP switch (SW2) toselect the operating mode, tone, and volume. See Figure 4.Figure 4: Mode of Operation switch settings1. Power selection jumpers2. SW2 configuration switch3. Tone4. Addressing mode5 Visual indicator operatingmode6. VolumeSetting the addressing modeConfigure the base sounder to operate with or without adetector at the same address as shown in Table 2.Table 2: Setting address modeSwitch SettingSW2-4 OFF The sounder is stand-alone with a uniqueloop address not used by another detector.SW2-4 ON The sounder shares the address with adetector to expand the number of devicessupported by the loop.Configure the base sounder to enable or disable the visualindicator as shown in Table 3.Table 3: Setting Visual Indicator operating modeSwitch SettingSW2-5 ON Enable thevisual indicator.SW2-5 OFF Disable thevisual indicator.Not recommended withSilent tone.Setting the volumeUse SW2-6 and SW2-7 to set the volume. Level 1 is the lowestvolume setting, and level 4 is the highest as shown in Table 4.Refer also to the measured anechoic sound levels in Figure 7.Table 4: Volume settings00 – Level 1 10 – Level 2 01 – Level 3 11 – Level 4Average dBA measurement3 dBA less thanlevel 2.3 dBA lessthan level 3.3 dBA lessthan level 4.Certified tones[1].[1] UK-continuous, UK intermittent, UK two-tone are EN 54-3compliant.Setting the toneThe control panel can operate the sounder in two different pre-programmed tones, by selecting SW2-1, SW2-2, and SW2-3.Refer to Table 5 Tone settings.Note: Two additional tones are available, the Class changeand the Visual indicator only tone. However, these tones maynot be available for legacy control panels. Please refer to theconfiguration options of your control panel to confirm toneavailability.Table 5: Tone settingsDevice mode SW2 switch setting -1-2-3 Primary warning Secondary evacuation Attention (nonfire)ZP755 0 UK intermittent UK continuous Class changeZP755 1 UK continuous UK two-tone Class changeZP755 2 UK two-tone UK intermittent Class changeZP755 3 Australian whoop Australian alert Class changeZP755 4 Swedish tone Dutch slow whoop Class changeZP755 5 ISO8201 French two-tone Class changeZP755 6 German Visual indicator only Class changeZP754 7 UK intermittent UK continuous Class change123 645 |
Related manuals for Ziton ZP755BV-4P
Ziton ZP755R-2 Installation Sheet
Ziton ZP787-3 Installation Sheet
Ziton ZP787-3 Installation Sheet
Ziton ZP2-LB Installation Sheet
Ziton ZP700 Series Installation Sheet
Ziton ZR432-2P Installation Sheet
Ziton ZR432-2P Installation Sheet
Ziton ZP1-F2 Installation Manual
Ziton ASWP-RF Installation Manual
Ziton ZP2 Series Quick Installation Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved