21Installation instructions802742UK V4.00 Sept 2018 - Zip HydroTap IndustrialTechnical supportTel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.ukBooster system3.2 Installation procedureSite requirements• Booster must only be installed in a frost-free area. Never expose booster to frost.• The booster is designed for wall mounted installation and must be installed with water connectors facing upwards.• The booster is protected against water ingress to class IP 25.• The 500mm braided hoses supplied with the booster cannot be lengthened.• The 90° elbow hose ends should be fitted to the inlet and outlet connections on top of the booster.• The hot water outlet hose must be thermally insulated with the insulation provided.Tilt forward Lift upReleaseNote Remove the wall mounting chassis from the rear of the booster for wall mounting.Take care notto break thelower clipswhen removingor installing thebooster.!Attach3.3 Booster installation see diagrams below• To remove the mounting chassis, insert a flat blade screwdriver all the way into the lock.• Gently angle the screwdriver upwards by approximately 10°.• Pull the booster forwards by approximately 15°.• Carefully pull the booster upwards to complete the removal process. Take care not to break the lowerclips.• Attach the mounting chassis horizontally to the wall / cupboard wall.• To install, clip the booster into the on the mounting chassis and snap into position (see installationbelow).Install