Zeta ZT-CP3 Manual
ZT-CP3 Zeta Conventional Manual Call Point RangeThis unique manual call point mimics the feel of breaking glass whilst offering the user the benefits and safety advantages of aglass-free resettable operating element. Once activated a warning flag drops in to view easily identifying the call point that hasbeen operated .A key can the reset the unit. The call point provides an ideal solution for most conventional fire alarm systems.It is ideal for industries that are sensitive to broken glass as well as areas that suffer from a high number of false activation ssuch as; schools, shopping centres and other public places.Wall PlateCoverOperatingElementReSet Key (1)providedReSet Call Point Surface MountingBack Box (Colour Matched)(Optional)Screw No. 8 x 1.5(2) provided(Surface Models only)Flush MountingSurface MountingScrew 3.5 x 3.5(2) provided(Flush Models only)SSurface Mountin12Dia B.Step 1Carefully attach the ReSet Call Point to thetop of the back box (Dia A.) and hinge downto the points where the cover rests on the topof the clip (Dia B.)Step 2Firmly push down on the cover to engage withclip. This should create a positive clickingsound which ensures that the clip has beencorrectly engaged (Dia C.)NB: If unsure if the clip has engaged with theback box, *IMPORTANT* release the coverfollowing Step 3. When back in the positiondemonstrated in Dia B. repeat Step 2.Dia C.Step 3 - Detaching the cover from theback box1. Insert key into the bottom of the ReSetcover2. Keep the key inserted and with your handpull the cover towards you (Dia D.)Dia A.Methods of mountingADia D.Flush InstallationThe call point is provided with a wall plate that isdesigned to fit directly onto a standard UK single35mm deep flush box.Secure the wall plate to the flush mount box withthe screws provided. Carefully attach the callpoint to the top of the wall plate and hinge downto snap securely into place.Surface InstallationNB: For security reasons the call point isdeliberately difficult to remove from the backbox once fitted. Please ensure that the callpoint is installed correctly before snappingclosed.The call point can be supplied with its ownsurface mounting back box, 20mm entry holescan be easily cut using the template provided oneach pack box. (See illustration below).With the screws provided, fix the back box to thewall. Carefully attach the call point to the top ofthe back box, hinge down to snap securely intoplace.87 mm 23 mmCOVEROPERATING ELEMENT35 mm 87 mm87 mmBACK BOXDimensions |
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved