-05-C. Window type methodD. Wall mounted type methodFront cover size:254mmX254mmWindow frame size:210mmX219mmMain body thickness:160mm.*Remark: Window typeinstallation must betransverse installation.Nails fixed hole Main body fixed screw1.Install at the place of the aluminum framed window or replace the exhaust fan in thebathroom2.Fix the window kit to the frame of the aluminum window( waterproof glue must be usedfor waterproof)3.After connecting the power cord, embed the main body into the hole with screws.1. Applicable for the bathroom without ceiling.2. Fix the wall kit to the wall, then embed the main body on the wall kit.3. Set the exhaust pipe(4” inner diameter 100mm) to the glass of window, and fix it to theadaptor with tape or metal clamp.4. Applicable size of the main body: 254mmX254mm,Thickness of the main body: 160mm.5.The minimum distance between the surrounding structures should be 50 cm.≥20mm ≥20mmWall WallThe machine needs≥20mm from the wall 2 sidesThe vent is under thestainless steel coverand cannot be covered