Zamel EXTA PBM-02 Instruction Manual
BISTABLE RELAY PBM-02 INSTRUCTION MANUALAPPEARANCEver. 0.4.2 _ 2006.06.26_08:00FEATURESTECHNICAL PARAMETERSDESCRIPTIONPBM - 02Input (supply) terminals : L, NInput rated voltage: 230 V~Input voltage tolerance: from -15 to +10 %Nominal frequency: 50 / 60 HzRated power consumption: 24 mASupply voltage control indicator: LED greenRelease terminals: IN, IN, INRelease control current: 930 μACentral control terminals: Set, ResetPower/relay supply indicator: LED redRelay operating indicator: TEST buttonOutput relay parameters: 1NO - 16 A / 250 V AC1 4000 VANumber of terminal clamps: 10Section of connecting cables: from 0,2 to 2,50 mm2Ambient temperature range: from -20 to +45 o COperating position: freeMounting: TH35 rail (PN-EN 60715)Protection degree: IP20 (PN-EN 60529)Protection class: IIOvervoltage category: IIPollution degree: 2Rated impulse withstand voltage: 1 kV (PN-EN 61000-4-5)Dimensions (height / width / depth): monomodular (17,5 mm) 90x17,5x66 mmWeight: 80 gReference standards: PN-EN 60669-1; PN-EN 60669-2-1PN-EN 61000-4-2,3,4,5,6,11The bistable relay PBM-02 is used tocontrol lighting or other devices by meansof monomodular pushbuttons connectedin a parallel way. Pushing any button cau-ses switching on or switching off the de-vices connected to output terminals. Thecontrolling impulse can be L or N line sig-nal. The Set and Rest control inputs allowcentral control of a relay group. Using theinner relay memory allows to rememberits current mode in cases of power supplyloss.Zakład Mechaniki i ElektronikiZAMEL sp.j.J.W. Dzida, K. Łodzińskaul. Zielona 27, 43-200 Pszczyna, PolandTel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04www.zamel.pl, e-mail: marketing@zamel.plThe device is desig-ned for one-phase in-stallation and must beinstalled in accordancewith standards valid ina particular country.The device should beconnected according to the details inclu-ded in this operating manual. Installation,connection and control should be carriedout by a qualified electrician staff, who actin accordance with the service manualand the device functions. Disassemblingof the device is equal with a loss of gua-rantee and can cause electric shock. Be-fore installation make sure the connec-tion cables are not under voltage. Thecruciform head screwdriver 3,5 mm sho-uld be used to instal the device.Impropertransport, storage, and use of the deviceinfluence its wrong functioning. It is notadvisable to instal the device in the follo-wing cases: if any device part is missingor the device is damaged or deformed. Incase of improper functioning of the devi-ce contact the producer.CAUTIONی Bistable lighting control,ی input rated indicator – LED green,ی relay mode indicator – LED red,ی central control function,ی relay mode memory,ی system releasing from the L or Ncable,ی cooperation with monostable pus-hbuttons equipped with illuminationlamps,ی TEST function,ی double-wire controll installation,ی voltage relay output - one NO (normaclosed) contact max 16 A capacity.Output (load) relaySupply voltage control indicatorInput supply terminals (L) Input supply terminals (N)Relay testPower/relay supply indicatorCentral control terminals (S, R)Release terminals(IN, IN, IN)terminals (11, 11, 14) |
Related manuals for Zamel EXTA PBM-02
Zamel Exta PBM-03 Instruction Manual
Zamel Exta PBM-07 Manual Instruction
Zamel exta PBM-07 Manual Instruction
Zamel EXTA PBM-03 Instruction Manual
Zamel Exta PCM-02/U Instruction Manual
Zamel EXTA PBP-01 Instruction Manual
Zamel PBM-01 Instruction Manual
Zamel exta PCM-01 Instruction Manual
Zamel exta PPM - 05 Instruction Manual
Zamel EXTA PCP-04 Instruction Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved