ZKTeco C3-200 Installation, Instruction And Service Manual
Also see for C3-200: User manualUser manual
4.LED indicators, Wires, Auxiliary Input and OutputNotes:1)Meaning of LED indicators:LINK indicator(green): always(green) indicates TCP/IPACT indicator(yellow): flashing indicates data is in transmittingTX indicator(yellow): flashing indicates it is sending data throughRX indicator(green): flashing indicates it is receiving data throughAuxiliary output indicator(green):always(green) indicates it is in use.Lock indicator(green):always(green) indicates lock is open.POWER indicator(red): always(red) indicates control panel power is on.RUN indicator(green): flashing indicates the system works normally.CARD indicator(yellow): flashing indicates card is punched on reader.A Use 2-conducotor power cord2)Recommended use of wires:3)The auxiliary input may be connnected to infrared body detectors,4)The auxiliary output may be connected to door bells,alarms,etc.B Use 6-conductor wire between wiegand reader and control panelC Use 4-conducotor lock power cord (RVV 4*0.75mm)D Use 2-conducotor switch power cord(RVV 2*0.5mm)communication is proper;alam switches,etc.through TCP/IP communication.RS485 communication.RS485 communication.(RVVP 6*0.5mm) (Choose the appropriate cord for the interfaceyou connect, such as 6,8,10 cord.)C3-200 Installation Instructions and Connection GuideVersion:1.2 Date: Jan. 20141.Cautions1 23Please note the following cautions. Mis-operation may lead to personal injury orequipment failure:1)Do not energize the system before installation is complete; never carry outinstallation activities when the system is energized.2)All peripheral devices must be grounded.3)The conduits of wires under relay must be matched with metaled conduits, otherwires can use PVC conduits.4)It is strongly recommended that the length of exposed part of any connection cableshould not be longer than 4 mm. Professional clamping tools may be used to avoidunintentional contact of exposed wires to avoid short-circuit or communication failure.5)It is recommended that card readers and buttons be installed at height of 1.4m-1.5mabove ground.6)It is recommended to use the power supply for control panel, and external powersupply for each lock.7)The appliance shall be installed and wired in accordance with national electricalcode and by qualified personnel only.Description of normal working state:Connect the system to the power supply. If the system works properly, the POWERindicator (red) is lit constantly and the RUN indicator (green) flashes.Valve regulated lead-acid battery:Constant voltage charge voltage regulationCycle use : 14.5V~14.9V(25)Initial current: less than 2.88AStandby use: 13.6V~13.8V(25)Capacity: 12V, 7.2Ah/20hr,Battery Type: LC-RA127R2T1Caution:Do not charge in a gas tight container.Do not short the battery terminals.Do not incinerateFlush with water at once if contact is made withelectrolyte (Acid)Do not attempt to disassemble the battery.Get through the thread hole Fixed caseControl panelThe chargingcircuit boardBackup batteryHeatdissipationhole Thread hole Key holeWiring the Control Panel, The ChargingCircuit Board and Backup BatteryPOWER2.Fixed and InstallationGNDINBUTTON2GNDGND+12V+12VWD1WD1WD0WD0READER3GLEDGLEDBEEPBEEPGND+12VWD1WD0READER2GLEDBEEPAUX1 AUX2 EXT BUTTON1 READER1+12VGNDWD1WD0GLEDBEEP+12VGND485-485+GNDGNDINININGNDTXRXACTLINKPOWER CARDRUNLAN11TXRXV+POWERPCNCNCCOMCOMNONOCOMCOMNONONCNCLOCK1 LOCK2GNDGNDSENSENV-GND485-485+AUXOUT1 AUXOUT2 LOCKGND+12V1 2 3 4ON5 6 7 8SD cardAdvanced Access ControlREADER4GNDINBUTTON2GNDGNDWD1WD1WD0WD0READER3GLEDGLEDBEEPBEEPGNDWD1WD0READER2GLEDBEEPAUX1 AUX2 EXT BUTTON1 READER1GNDWD1WD0GLEDBEEPGNDGNDGNDINININGNDTXRXACTLINKPOWER CARDRUNLAN11TXRXPOWERPCNCNCCOMCOMNONOCOMCOMNONONCNCLOCK1 LOCK2GNDGNDSENSENGNDAUXOUT1 AUXOUT2 LOCKGNDSD cardAdvanced Access ControlREADER4V+V-+12VLAN485+485-+12V+12V+12V+12V485+485-+12VON1 4 62 3 5 7 8AACCDDDDDBBDBBPC RS485 interfaceEthernet interfaceDip switchAuxiliary output1Auxiliary output2Lock1Lock2Power of lockPower of control panelAuxiliary input1Auxiliary input2ExtendedRS485 output1# Door Button1# DoorWiegand reader1# DoorWiegand reader2# Door Button2# DoorWiegand reader2# DoorWiegand readerNote:AUX Input (1-2) connect to theinfrared human body induction,wireless exit button, windowssensor with dry contact (novoltage);Note:AUX Input (1-2) connect way issameNote:Output ElectricalParameters:Rated Voltage:12V(DC)Rated Current:0.5ANote:1、Door button (1-2) connect to Exitbutton with dry contact.(no voltage);2、Wiegand Reader (1-4) connect toWG Reader;Port (+12V)Output ElectricalParameters:Rated Voltage: 12V(DC)Rated Current: 0.5APort (BEEP GLED) Output ElectricalParameters:Rated Voltage: 5V(DC)Raged Current: 0.5mANote:AUX Output (1-2)connect to alarm, doorbell and so on;Port (NO,COM,NC)Electrical Parameters:MAX Voltage:36V(DC)MAX Current: 1.25ANote:AUX Output (1-2)connect way is sameSD Card Interface;Function: Backup Access Control LogsNote:Lock Power InputElectrical Parameters:Rated Voltage: 36V(DC)Rated Current: 2ADevice Power InputElectrical Parameters:Rated Voltage: 12V(DC)Rated Current: 2ANote:Lock(1-2):Port (SEN)connect to door sensor single withdry contact (no voltage);Port (NO, COM, NC) Electrical Parameters:MAX Voltage: 36V(DC)MAX Current: 2ANote:When you select Wet mode, The power is Lockpower, Lock (1-2) total load don’t more thanLock power Rated current (2A)Note:Lock (1-2) connect way is same |
Related manuals for ZKTeco C3-200
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved