ZK Technology SCR100 Installation Manual
-+-+DC12V++--+DC12VGND+12V-+DC12V+--+-++--+DC PowerRS485 TCP/IP① ②③④ ⑤⑥-GND+12VAL+AL-NCCOMNOBUTGNDSESBELL+BELL-GND+12VGND+12VAL+AL-NCCOMNOBUTGNDSESBELL+BELL--+GND+12VAL+AL-NCCOMNOBUTGNDSESBELL+BELL-AL+AL-NCCOMNOBUTGNDSESBELL+BELL-AL+AL-NCCOMNOBUTGNDSESBELL+BELL-Installation Guide for SCR100 DeviceI. Install deviceII. Access control system overviewRS232/RS485ConverterCardreaderReleasebuttonAlarmLock Doorsensor! Warning: Don’t connect wires with power on!III. Connect to door lock1)device and lock share power supplyNC lock NO lockNotice:If lock’s working power is DC12V,and working current is least 1000mA lessthan that of access control device powersupply, wiring with sharing power supplycan be adopted.Notice: Wiring with lock power suppliedindependently is recommended for thefollowing states:1) Lock’s working power is DC 12V,power’s current isdevice not 1A morethan that of lock.2)Lock’s standard voltage is not DC12V.3)The distance between lock and deviceis long.NO lockNC lockⅣ. Connection with other deviceAlarmAlarmpowerReleasebuttonDoor sensor2)device and lock don’t share power supplyDC PowerDC Power DC Power1)Post the mounting template onthe wall. Drill holes according tothe marks on the template.(Holesfor screw and wiring)3) Take away the screw onthe bottom of device2)Take off the water-proof cushion5)Fix the cushion and plate onthe wall4) Release the mounting plate 6) Fix the device with the plateafter all wiring completed⑤Access control device can be connected with external out-goswitch, which provides convenience to open door from the inside.① When a registered person verified, the access control devicewill export signal to open the door.② Door sensor will detect on-off state to sense whether the dooris opened by accident or the door is not closed well, alarm will③If access control device is torn down illegally, or door sensoris abnormal, or menace alarm gives off, the device will export④ Connect a Weigand reader to work as a controller.⑥Access control software to manage multi devices via RS485Access control systemalarm signal.or TCP/IP.The device could connect to NC or NO locks, the connection terminal is not same, please according to the followingdiagram to make connection.1)The rating output of the alarm no more than DC12V.The device’s working voltage is DC12V, withworking current 500mA,standby current 50mA .Make sure the connection as the diagram(Don’tconnect the poles in reverse.).Ⅴ.Power connectionbe given off under abnormal condition.Notice:2)The device has no bell button,so BELL+ and BELL-terminals don’t work temporarily.+- FR 107+- FR 107+- FR 107+- FR 107 |
Related manuals for ZK Technology SCR100
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved