2 CHECKING ON DELIVERYE - 82.4 Mounting FC100 UnitMount a FC100 Unit on a SGDH SERVOPACK in the following manner. Provide the screwsfor connecting ground wire as shown below.MountingMethod SERVOPACK Type Screw RemarksBasemountedSGDH-A3 to 02BESGDH-A3 to 10AEM3×10 round head screws(with spring washer andplain washer)Attachments.SGDH-15 to 50AESGDH-05 to 30DEM4×10 round head screws(with spring washer andplain washer)Attachments.SGDH-60/75AE M4×8 round head screws(with spring washer andplain washer)Use the screw of the front panel.RackmountedSGDH-A3 to 02BE-RSGDH-A3 to 50AE-RSGDH-05 to 30DE-RM4×6 round head screws(with spring washer andplain washer)Attachments.Note : Make sure that spring washers andplain washers are used for mounting.(Otherwise, the screw for connectingground wire sticks out from the otherside of the flange, and the SERVO-PACK cannot be mounted properly.)DuctventilatedSGDH-60/75AE-P M4×8 round head screws(with spring washer andplain washer)Use the screw of the front panel.1. Remove the connector cover mounted on CN10 of SERVOPACK.MODE/SET DATA/CHARGE POWERSGDH−SERVOPACKYASKAWACN10Connectorcover2. Mount a FC100 Unit.SGDH−SERVOPACKYASKAWAF 1C 00CN4CN10Connector (to SERVOPACK)